{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9KF71310","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9KF71310","canonicalUrl":"https://aoctrl.com/schneider/A9KF71310","factsUrl":"https://aoctrl.com/api/mcp/products/A9KF71310","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 K60, A9KF71310, miniature circuit breaker, 3P, 10 A, C-curve, 10 kA Icn at 415 V AC, DIN rail mount.","salesMarkdown":"The Schneider Electric A9KF71310 is a 3-pole miniature circuit breaker from the Acti9 K60 series, rated 10 A with a C-curve trip characteristic. It is a thermal-magnetic MCB designed for distribution in AC networks at 50/60 Hz. IP20 finger-safe front is standard for enclosed panel use. The toggle control provides local on/off switching with a contact-position indicator absent — you read the handle position directly. The C-curve with magnetic trip at 5…10 x In means it holds through transformer inrush and motor starting currents up to about 50–100 A for short durations, then trips instantaneously on a hard short. Electrical and mechanical endurance are both 20,000 cycles, which is typical for a distribution MCB. The part is tropicalised to class 2 per IEC 60068-1, meaning it withstands damp heat — relevant for installations in high-humidity environments. Operating altitude is 0…2000 m; relative humidity up to 95% at 55 °C. Pollution degree 2 covers normal industrial environments with only non-conductive pollution.","metaTitle":"Schneider Electric A9KF71310 Acti9 K60 MCB, 10A 3P C-Curve","metaDescription":"Schneider Electric A9KF71310 Acti9 K60 miniature circuit breaker, 10A rated current, 3-pole, C-curve, 10 kA breaking capacity at 415 VAC. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Circuit Breaker Accessories"],"specifications":{"Depth":"70 mm","Range":"Acti9","Width":"54 mm","Colour":"White","Height":"81 mm","Standards":"EN/IEC 60898-1","Curve code":"C","9 Mm Pitches":"6","Control type":"Toggle","Network type":"AC","Product name":"Acti9 K60","Mounting mode":"Fixed","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Without","Mounting support":"DIN rail","Pollution degree":"2","Breaking capacity":"10000 A Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"K60H","Network frequency":"50/60 Hz","Poles description":"3P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","Operating altitude":"0...2000 m","[In] rated current":"10 A","Overvoltage category":"II","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Tunnel type terminals (downstream) 1...25 mm² rigid Tunnel type terminals (upstream) 1...25 mm² rigid Tunnel type terminals (downstream) 1...16 mm² flexible Tunnel type terminals (upstream) 1...16 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Without","Number of protected poles":"3","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60898-1","Contact position indicator":"No","[Ui] rated insulation voltage":"500 V AC 50/60 Hz","Ambient air temperature for storage":"-25...85 °C","Ambient air temperature for operation":"-5...55 °C","[Ics] rated service breaking capacity":"7500 A 75 % conforming to EN/IEC 60898-1 - 415 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"4 kV","Comb busbar and distribution block compatibility":"Downstream: biconnect"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9KF71310/acti9-k60h-3p-10-a-c-curve-10000-a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9KF71310/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for A9KF71310?","answer":"Submit an RFQ for the A9KF71310. Pricing and availability are confirmed at quote time through independent distribution channels."},{"question":"What is the breaking capacity of A9KF71310?","answer":"The A9KF71310 has a breaking capacity of 10,000 A Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1."},{"question":"What standards does A9KF71310 comply with?","answer":"The A9KF71310 complies with EN/IEC 60898-1 and is suitable for isolation per that standard. It also meets tropicalisation class 2 per IEC 60068-1 and limitation class 3 per EN/IEC 60898-1."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9KF71310","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9KF71310 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}