{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9KF71325BQ","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9KF71325BQ","canonicalUrl":"https://aoctrl.com/schneider/A9KF71325BQ","factsUrl":"https://aoctrl.com/api/mcp/products/A9KF71325BQ","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 K60 miniature circuit breaker, 3-pole, 25 A, C-curve, 10 kA breaking capacity at 415 V AC, DIN rail mount, IP20.","salesMarkdown":"The A9KF71325BQ: Mounts on a standard DIN rail — 6 module pitches (54 mm wide) — and accepts rigid conductors up to 25 mm² or flexible up to 16 mm² in tunnel terminals. IP20 rated, so it's for inside a panel, not exposed.","metaTitle":"Schneider Electric A9KF71325BQ Acti9 K60 MCB, 25 A, C-Curve,","metaDescription":"Schneider Electric A9KF71325BQ Acti9 K60 miniature circuit breaker, 25 A, C-curve, 10 kA at 415 V AC, 3-pole, DIN rail. Current production. Available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Circuit Breaker Accessories"],"specifications":{"Depth":"70 mm","Range":"Acti9","Width":"54 mm","Colour":"White","Height":"81 mm","Standards":"EN/IEC 60898-1","Curve code":"C","9 Mm Pitches":"6","Control type":"Toggle","Network type":"AC","Product name":"Acti9 K60","Mounting mode":"Fixed","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Without","Mounting support":"DIN rail","Pollution degree":"2","Quantity per set":"Set of 4","Breaking capacity":"10000 A Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"K60H","Network frequency":"50/60 Hz","Poles description":"3P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","Operating altitude":"0...2000 m","[In] rated current":"25 A","Overvoltage category":"II","Trip unit technology":"Thermal-magnetic","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Tunnel type terminals (downstream) 1...25 mm² rigid Tunnel type terminals (upstream) 1...25 mm² rigid Tunnel type terminals (downstream) 1...16 mm² flexible Tunnel type terminals (upstream) 1...16 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Without","Number of protected poles":"3","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60898-1","Contact position indicator":"No","[Ui] rated insulation voltage":"500 V AC 50/60 Hz","Ambient air temperature for storage":"-25...85 °C","Ambient air temperature for operation":"-5...55 °C","[Ics] rated service breaking capacity":"7500 A 75 % conforming to EN/IEC 60898-1 - 415 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"4 kV","Comb busbar and distribution block compatibility":"Downstream: biconnect"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9KF71325BQ/acti-9-k60h-3p-25-a-c-curve-10-ka-set-of-4/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9KF71325BQ/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy A9KF71325BQ and how do I get a price?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is the closest pin-compatible alternative to A9KF71325BQ in this component family?","answer":"Within the Acti9 range, the K60 series shares the same physical footprint and DIN-rail mounting. The key difference is the curve code and rated current — the A9KF71325BQ is a 25 A, C-curve. A B-curve variant would trip faster on inrush, while a D-curve handles higher surge loads. No direct pin-compatible substitute outside the family is listed."},{"question":"What is A9KF71325BQ's listed depth (70 mm) on this component line?","answer":"The depth is 70 mm, with a height of 81 mm and width of 54 mm (6 module pitches)."},{"question":"What compliance documentation does this brand provide for A9KF71325BQ (RoHS, REACH, UL, IEC)?","answer":"The breaker is certified to EN/IEC 60898-1 and carries IP20 per IEC 60529. It is suitable for isolation per the same standard. The evidence does not list RoHS, REACH, or UL marks specifically, but Schneider typically provides these on request for Acti9 products."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9KF71325BQ","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9KF71325BQ when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}