{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9KF71416BQ","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9KF71416BQ","canonicalUrl":"https://aoctrl.com/schneider/A9KF71416BQ","factsUrl":"https://aoctrl.com/api/mcp/products/A9KF71416BQ","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 K60, miniature circuit breaker, 4P, 16 A, C-curve, 10 kA Icn at 415 V AC, DIN rail mount, thermal-magnetic trip.","salesMarkdown":"The A9KF71416BQ is a Schneider Electric Acti9 K60 miniature circuit breaker rated 16 A with a C-curve magnetic trip (5 to 10 times In). That 10 kA Icn at 415 V AC per EN/IEC 60898-1 means it can safely interrupt fault currents up to 10,000 A in a 415 V AC distribution panel — enough headroom for most commercial and light industrial sub-distribution boards where the prospective short-circuit current stays under that threshold. The thermal-magnetic trip unit handles overloads (thermal bimetal) and short-circuits (magnetic coil) in one compact package, with 20,000 electrical and 20,000 mechanical cycles giving a solid service life for a panel that sees regular switching. Tunnel terminals accept 1–25 mm² rigid or 1–16 mm² flexible copper, with a 2 N·m tightening torque and 14 mm strip length. IP20 finger-safe terminals are standard for enclosed panels; the IP rating is for the terminal area only, not the breaker body in a wet environment.","metaTitle":"Schneider Electric A9KF71416BQ Acti9 K60 MCB, 16 A C-Curve 4","metaDescription":"Schneider Electric A9KF71416BQ Acti9 K60 miniature circuit breaker, 16 A rated current, C-curve, 4 poles, 10 kA breaking capacity at 415 V AC. Complies with EN/IEC 60898-1. Availab","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Circuit Breaker Accessories"],"specifications":{"Depth":"70 mm","Range":"Acti9","Width":"72 mm","Colour":"White","Height":"81 mm","Standards":"EN/IEC 60898-1","Curve code":"C","9 Mm Pitches":"8","Control type":"Toggle","Network type":"AC","Product name":"Acti9 K60","Mounting mode":"Fixed","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Without","Mounting support":"DIN rail","Pollution degree":"2","Quantity per set":"Set of 3","Breaking capacity":"10000 A Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"K60H","Network frequency":"50/60 Hz","Poles description":"4P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","Operating altitude":"0...2000 m","[In] rated current":"16 A","Overvoltage category":"II","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Tunnel type terminals (downstream) 1...25 mm² rigid Tunnel type terminals (upstream) 1...25 mm² rigid Tunnel type terminals (downstream) 1...16 mm² flexible Tunnel type terminals (upstream) 1...16 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Without","Number of protected poles":"4","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60898-1","Contact position indicator":"No","[Ui] rated insulation voltage":"500 V AC 50/60 Hz","Ambient air temperature for storage":"-25...85 °C","Ambient air temperature for operation":"-5...55 °C","[Ics] rated service breaking capacity":"7500 A 75 % conforming to EN/IEC 60898-1 - 415 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"4 kV","Comb busbar and distribution block compatibility":"Downstream: biconnect"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9KF71416BQ/acti-9-k60h-4p-16-a-c-curve-10-ka-set-of-3/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9KF71416BQ/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of A9KF71416BQ?","answer":"10,000 A Icn at 415 V AC, 50/60 Hz, conforming to EN/IEC 60898-1. That's the rated short-circuit capacity for this 4-pole, 16 A C-curve MCB."},{"question":"Where can I buy A9KF71416BQ?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for the latest position."},{"question":"What standards does A9KF71416BQ comply with?","answer":"It complies with EN/IEC 60898-1 for miniature circuit breakers. It also meets IEC 60068-1 for tropicalisation (class 2) and IEC 60529 for IP20 finger protection."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9KF71416BQ","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9KF71416BQ when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}