{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9KR14263BQ","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9KR14263BQ","canonicalUrl":"https://aoctrl.com/schneider/A9KR14263BQ","factsUrl":"https://aoctrl.com/api/mcp/products/A9KR14263BQ","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 ID K RCCB, A9KR14263BQ, 2P, 63 A rated current, 300 mA earth-leakage sensitivity, Type AC, clip-on DIN rail mount, 50 Hz.","salesMarkdown":"The Schneider Electric A9KR14263BQ is an Acti9 ID K residual current circuit breaker (RCCB) — a 2-pole, 63 A, 300 mA sensitivity Type AC device for 220–240 V AC 50 Hz networks. 63 A rated current (In) and 300 mA earth-leakage sensitivity define the load and protection envelope. Type AC (sinusoidal AC residual currents only) and instantaneous time delay mean it trips on pure AC leakage without intentional delay. That is standard for general-purpose RCCB duty; it is not suitable for pulsating DC or smooth DC residual currents (those need Type A or Type B). Rated breaking and making capacity Idm 630 A / Im 630 A covers the short-circuit withstand for a 63 A device in a domestic or light commercial panel. The voltage-independent tripping technology means it operates even if the supply voltage is lost — the coil is not powered during normal running. Clip-on DIN rail mount, 36 mm wide (4 x 9 mm pitches), 81 mm high, 68 mm deep. Neutral on the left. Terminals accept 1–35 mm² rigid or 1–25 mm² flexible conductors top and bottom; strip length 14 mm, tightening torque 3.5 N.m. IP20 on the device body, IP40 inside a modular enclosure. That depth (68 mm) fits standard shallow consumer units and panel enclosures — no extra depth clearance needed beyond the usual 80–100 mm backbox. Listed as current production. Certified to IS 12640-1 and EN/IEC 61008-1/2-1.","metaTitle":"Schneider Electric A9KR14263BQ Acti9 ID K RCCB, 63A, 300mA,","metaDescription":"Schneider Electric A9KR14263BQ Acti9 ID K RCCB, 63A rated current, 300mA sensitivity, 2-pole, Type AC, clip-on DIN rail. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"68 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"81 mm","Standards":"IS 12640-1 EN/IEC 61008-1 EN/IEC 61008-2-1","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 ID K","Mounting mode":"Clip-on","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"2","Quantity per set":"Set of 6","Device short name":"ID K","Network frequency":"50 Hz","Poles description":"2P","Relative humidity":"95 % at 55 °C","Tightening torque":"3.5 N.m top or bottom","[In] rated current":"63 A","Electrical durability":"AC-1: 4000 cycles","Mechanical durability":"5000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Biconnect top or bottom 1...35 mm² rigid Biconnect top or bottom 1...25 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Device location in system":"Group incomer","Earth-leakage sensitivity":"300 mA","Product or component type":"Residual current circuit breaker (RCCB)","Contact position indicator":"No","Electromagnetic compatibility":"8/20 µs impulse withstand, 200 A conforming to EN/IEC 61008-1","[Ui] rated insulation voltage":"440 V AC 50 Hz","Earth-leakage protection class":"Type AC","[Ue] rated operational voltage":"220...240 V AC 50 Hz","Rated breaking and making capacity":"Idm 630 A Im 630 A","Ambient air temperature for storage":"-25...85 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-5...55 °C","[Uimp] rated impulse withstand voltage":"4 kV","Rated conditional short-circuit current":"GL63: Inc 4.5 kA K60: Inc 6 kA"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9KR14263BQ/acti-9-id-k-rccb-2p-63a-300ma-type-ac-set-of-6/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9KR14263BQ/alternatives.json"},"ai":{"faq":[{"question":"What is A9KR14263BQ's listed depth?","answer":"The depth is 68 mm."},{"question":"What is the Acti9 range?","answer":"Acti9 is Schneider Electric's modular DIN-rail range of circuit protection and control devices for residential, commercial, and light industrial installations. The A9KR14263BQ is part of the Acti9 ID K sub-family of RCCBs."},{"question":"What compliance documentation does this brand provide for A9KR14263BQ?","answer":"The A9KR14263BQ is certified to IS 12640-1, EN/IEC 61008-1, and EN/IEC 61008-2-1. The manufacturer typically provides a declaration of conformity and test reports upon request through the supply chain."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9KR14263BQ","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9KR14263BQ when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}