{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9L08200","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9L08200","canonicalUrl":"https://aoctrl.com/schneider/A9L08200","factsUrl":"https://aoctrl.com/api/mcp/products/A9L08200","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iPRD8, Type 2+3 surge arrester, 2P, 350V continuous, 230V AC rated, 8 kA max discharge, pluggable MOV cartridge, clip-on DIN rail mount.","salesMarkdown":"The A9L08200 is a Type 2 + 3 surge arrester from the Acti9 iPRD range, designed for electrical distribution networks. It uses MOV technology in a pluggable cartridge format, rated for 230 V AC (+/- 10 %) at 50/60 Hz with a maximum continuous operating voltage of 350 V common mode. This is a 2-pole unit (L/N) intended for TN-C-S earthing systems, and it clips onto a standard DIN rail — a straightforward panel integration for a distribution board or sub-distribution enclosure. The Type 2 + 3 classification (per EN 61643-11:2012 / IEC 61643-11:2011) means this arrester handles both main distribution board surges and equipment-level protection. The nominal discharge current is 2.5 kA common mode per path (L/PE and N/PE), with a maximum discharge current of 8 kA common mode. The voltage protection level stays under 1 kV at the Type 3 test. Temporary overvoltage handling is a practical concern: the unit withstands 337 V L/N for 5 seconds, and 1200 V N/PE for 200 ms in safe failure mode — meaning a neutral shift or brief utility swell won't necessarily blow the cartridge. The ground residual current is 0.6 mA (0.003 mA under one condition), well below nuisance-trip thresholds for most RCDs. Operating temperature range is -25 to 60 °C, storage -40 to 85 °C, with 5 to 95 % relative humidity — adequate for unheated electrical rooms and most indoor industrial environments. The pluggable cartridge design means you can replace the MOV module without rewiring the base — a time-saver during commissioning or after a surge event. The associated disconnector options include iC60L, iC60N, iC60H circuit breakers (10 A curve C) or gG fuses (25 A or 80 A), giving the panel builder flexibility in coordination with upstream protection.","metaTitle":"A9L08200 Acti9 iPRD Surge Arrester, 2P, 350V, Type 2+3","metaDescription":"A9L08200 Acti9 iPRD8 2P surge arrester, 230V AC, Type 2+3 MOV, 8kA max discharge, DIN-rail mount. Active production. Sourced to order. EN/IEC 61643-11.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"69 mm","Width":"36 mm","Colour":"White (RAL 9003)","Height":"85 mm","Standards":"EN 61643-11:2012 IEC 61643-11:2011","9 Mm Pitches":"4","Product name":"Acti9 iPRD","Mounting mode":"Clip-on (DIN rail)","Quality labels":"KEMA-KEUR NF","Earthing system":"TN-C-S","lifecycle_stage":"current","Range Of Product":"Acti9","Range of product":"IPRD","Device short name":"iPRD8","Poles description":"2P","Relative humidity":"5...95 %","Remote signalling":"Without","Tightening torque":"2.5 N.m","Compatibility code":"IPRD8","Device application":"Distribution","Operating altitude":"2000 m","Surge arrester type":"Electrical distribution network","Connections - terminals":"Tunnel type terminal (downside) 2.5...35 mm² Tunnel type terminal (upside) 2.5...35 mm²","IK degree of protection":"IK03 conforming to IEC 62262","Disconnector device type":"Associated circuit breaker iC60L 10 A curve C - Icu 25 kA Associated circuit breaker IC60N 10 A curve C - Icu 10 kA Associated circuit breaker iC60H 10 A curve C - Icu 15 kA Associated fuse gG 25 A - Icu 15 kA Associated fuse gG 80 A - Icu 50 kA","Maximum discharge current":"Common mode: 8 kA L/PE Common mode: 8 kA N/PE","Nominal discharge current":"Common mode: 2.5 kA (L/PE) Common mode: 2.5 kA (N/PE)","Product or component type":"Surge arrester with pluggable cartridge","Surge arrester class type":"Type 2 + 3","Surge arrester technology":"MOV","[Uoc] open circuit voltage":"10 kV type 3 common mode L/PE 10 kV type 3 common mode N/PE","[Ut] temporary overvoltage":"337 V L/N 5 s withstand 1200 V N/PE 200 ms safe failure mode","[Ipe] Ground residual current":"0.6 mA 0.003 mA","[Ue] rated operational voltage":"230 V AC (+/- 10 %) at 50/60 Hz","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...60 °C","Maximum [Up] voltage protection level":"Common mode Common mode Common mode Common mode <1 kV type 3 N/PE","[Uc] maximum continuous operating voltage":"Common mode: 350 V L/PE Common mode: 350 V N/PE"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$75.39","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/sg/en/product/A9L08200/iprd8-modular-surge-arrester-2p-350v/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9L08200/alternatives.json"},"ai":{"faq":[{"question":"What compliance documentation does this brand provide for A9L08200?","answer":"The A9L08200 carries KEMA-KEUR and NF quality labels and complies with EN 61643-11:2012 and IEC 61643-11:2011. The manufacturer typically provides a declaration of conformity covering these standards; consult the product documentation for RoHS/REACH status."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9L08200","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9L08200 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}