{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9L16445","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9L16445","canonicalUrl":"https://aoctrl.com/schneider/A9L16445","factsUrl":"https://aoctrl.com/api/mcp/products/A9L16445","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iPRD40r, Type 2 surge arrester, 3 poles, 340 V AC, 40 kA max discharge, with remote signalling, clip-on DIN rail mount.","salesMarkdown":"The A9L16445: It clips onto a DIN rail, occupying 6 modules of 9 mm pitch (54 mm total width), with a depth of 69 mm and height of 81 mm. That's a standard panel footprint — no surprises for a retrofit into an existing Acti9 distribution board. The headline numbers: 40 kA maximum discharge current (common mode, L/PE), 15 kA nominal discharge current per mode, and a total discharge capacity of 120 kA across all paths. The voltage protection level (Up) is clamped below 1.4 kV at Type 2 duty — that's the let-through voltage your downstream equipment sees during a surge event. Terminals are tunnel type, accepting 2.5 to 35 mm² on both the line and load side. Tightening torque is 2.5 N·m — standard for this conductor range. The unit ships with a white (RAL 9003) housing, which is the usual finish for Acti9 modular devices. It requires an associated external circuit breaker: Schneider specifies the iC60N, iC60H, or iC60L, all 40 A curve C, with interrupting capacities of 10 kA, 15 kA, or 25 kA respectively. That breaker is your overcurrent backup; the arrester itself handles the surge path. Remote signalling is built in — a single changeover contact (1 C/O) rated 0.25 A / 250 V AC, 50/60 Hz. Operating temperature range is -25 to 60 °C, storage from -40 to 85 °C, with relative humidity 5 to 90 %. Maximum operating altitude is 2000 m. IK03 impact resistance per IEC 62262.","metaTitle":"Schneider Electric A9L16445 Acti9 iPRD40r Surge Arrester, 3P","metaDescription":"Schneider Electric A9L16445 Acti9 iPRD40r Type 2 surge arrester, 3 poles, 340V AC, 40 kA max discharge, with remote signalling. Active production, quoted on request.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Color":"White (RAL 9003)","Depth":"69 mm","Width":"54 mm","Height":"81 mm","Voltage":"400 V AC (+/- 10 %) at 50/60 Hz","Application":"Distribution","Product Status":"Active","Temp Storage Max":"85 °C","Temp Storage Min":"-40 °C","Temp Operating Max":"60 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-40...85 °C","Ambient Air Temperature Operation":"-25...60 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/id/en/product/A9L16445/iprd40r-modular-surge-arrester-3-poles-340v-with-remote-transfer/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9L16445/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9L16445","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9L16445 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}