{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9L16678","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9L16678","canonicalUrl":"https://aoctrl.com/schneider/A9L16678","factsUrl":"https://aoctrl.com/api/mcp/products/A9L16678","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iPRD8r, Type 2+3 surge arrester, 4 poles, 460 V, with remote signalling, clip-on DIN rail mount.","salesMarkdown":"The Schneider Electric A9L16678 is an Acti9 iPRD8r modular surge arrester — a Type 2+3 device with four poles (4P), rated 230/400 V AC (±10 %) at 50/60 Hz. It uses MOV technology and clips onto a DIN rail, making it a straightforward fit inside a distribution panel for protecting sensitive downstream equipment against transient overvoltages. The maximum discharge current (Imax) is 8 kA per mode (L/PE, N/PE) in common mode, with a nominal discharge current (In) of 2.5 kA. That means it handles the typical surge from a nearby lightning strike or utility switching event without failing — the 8 kA figure is the single-event survival limit, while 2.5 kA is the repeated-duty rating you design to. The voltage protection level (Up) stays below 1.5 kV in Type 3 common mode, which is low enough to keep most power-supply and control electronics alive through a surge. It carries a total discharge current (Itotal) rating of 30 kA — that's the sum of all modes under a worst-case combined event, confirming the arrester can dump a lot of energy into the ground path in a single shot. Clip it onto a DIN rail inside the distribution board. The tunnel-type terminals accept 2.5 to 35 mm² conductors on both the line and load sides, so it handles standard panel wiring without adapters. The remote signalling contact (1 C/O, rated 0.25 A / 250 V AC) lets a PLC or building management system monitor the arrester's status — if the MOV cartridge degrades or blows, the contact changes state, so maintenance knows without opening the panel. Designed to EN 61643-11 and IEC 61643-11. Enclosure carries IK03 impact protection per IEC 62262. Operating temperature range is -25 to 60 °C, storage -40 to 85 °C, with relative humidity 5 to 90 %. Current-production part (lifecycle stage: current).","metaTitle":"Schneider Electric A9L16678 Acti9 iPRD8r Surge Arrester, 4P,","metaDescription":"Schneider Electric A9L16678 Acti9 iPRD8r Type 2+3 surge arrester, 4 poles, 460 V, with remote signalling. Active production. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Color":"White (RAL 9003)","Depth":"69 mm","Width":"72 mm","Height":"81 mm","Voltage":"230/400 V AC (+/- 10 %) at 50/60 Hz","Application":"Distribution","Product Status":"Active","Temp Storage Max":"85 °C","Temp Storage Min":"-40 °C","Temp Operating Max":"60 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-40...85 °C","Ambient Air Temperature Operation":"-25...60 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/ae/en/product/A9L16678/iprd-8r-modular-surge-arrester-4-poles-460-v-with-remote-transfer/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9L16678/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9L16678","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9L16678 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}