{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9L20200","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9L20200","canonicalUrl":"https://aoctrl.com/schneider/A9L20200","factsUrl":"https://aoctrl.com/api/mcp/products/A9L20200","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iPRD20 Type 2 surge arrester, 2P, 350 V, 20 kA max discharge, clip-on DIN rail, white (RAL 9003).","salesMarkdown":"The Schneider Electric A9L20200 is an Acti9 iPRD20 Type 2 surge arrester, 2-pole, rated 230 V AC (+/- 10%) at 50/60 Hz, with a maximum continuous operating voltage of 350 V common mode per the datasheet. It uses MOV technology and clips onto a DIN rail — standard panel integration for distribution boards. Nominal discharge current is 5 kA (common mode L/PE and N/PE); maximum discharge current is 20 kA (common mode). That 20 kA rating tells you this unit can safely divert a direct lightning-induced surge up to that level without failing short — it's sized for main distribution panels in TN-C-S earthing systems, not sub-panel or device-level protection. The Type 2 classification per EN 61643-11:2012 and IEC 61643-11:2011 means it's tested for the main distribution board location, handling the bulk of surge energy before it reaches sensitive loads downstream. The protection level (Up) is under 1.1 kV common mode — within tolerance for typical 230 V equipment impulse withstand. Temporary overvoltage (Ut) is 337 V L/N for 5 s withstand, and 1200 V N/PE for 200 ms safe failure mode — the MOV will thermally disconnect rather than rupture under sustained overvoltage. Ground residual current is 0.003 mA to 0.6 mA, which keeps leakage well below nuisance RCD trip thresholds. Clip-on DIN rail mounting, 36 mm wide (2 x 18 mm modular pitches), 69 mm deep, 85 mm high. Tunnel-type terminals accept 2.5 to 35 mm² on both top and bottom — solid or stranded copper, torque to 2.5 N·m. The white (RAL 9003) housing blends into standard distribution board layouts. Operating temperature range is -25 to 60 °C, storage -40 to 85 °C, with relative humidity 5 to 95%. IK03 impact rating per IEC 62262 means it withstands 0.35 J impacts — adequate for enclosed panel installation, not for exposed locations.","metaTitle":"Schneider Electric A9L20200 Acti9 iPRD20 Type 2 Surge Arrest","metaDescription":"Schneider Electric A9L20200 Acti9 iPRD20 Type 2 surge arrester, 2-pole, 350 V, 20 kA max discharge. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"69 mm","Width":"36 mm","Colour":"White (RAL 9003)","Height":"85 mm","Standards":"EN 61643-11:2012 IEC 61643-11:2011","9 Mm Pitches":"4","Product name":"Acti9 iPRD","Mounting mode":"Clip-on (DIN rail)","Quality labels":"NF KEMA-KEUR","Earthing system":"TN-C-S","lifecycle_stage":"current","Range Of Product":"Acti9","Range of product":"IPRD","Device short name":"iPRD20","Poles description":"2P","Relative humidity":"5...95 %","Remote signalling":"Without","Tightening torque":"2.5 N.m","Compatibility code":"IPRD20","Device application":"Distribution","Operating altitude":"2000 m","Surge arrester type":"Electrical distribution network","Connections - terminals":"Tunnel type terminal (downside) 2.5...35 mm² Tunnel type terminal (upside) 2.5...35 mm²","IK degree of protection":"IK03 conforming to IEC 62262","Disconnector device type":"Associated circuit breaker IC60N 20 A curve C - Icu 10 kA Associated circuit breaker iC60H 20 A curve C - Icu 15 kA Associated circuit breaker iC60L 20 A curve C - Icu 25 kA Associated circuit breaker NG125H 20 A curve C - Icu 36 kA Associated circuit breaker NG125L 20 A curve C - Icu 50 kA Associated fuse gG 40 A - Icu 15 kA Associated fuse gG 80 A - Icu 50 kA","Maximum discharge current":"Common mode: 20 kA L/PE Common mode: 20 kA N/PE","Nominal discharge current":"Common mode: 5 kA (L/PE) Common mode: 5 kA (N/PE)","Product or component type":"Surge arrester with pluggable cartridge","Surge arrester class type":"Type 2","Surge arrester technology":"MOV","[Ut] temporary overvoltage":"337 V L/N 5 s withstand 1200 V N/PE 200 ms safe failure mode","[Ipe] Ground residual current":"0.003 mA 0.6 mA","[Ue] rated operational voltage":"230 V AC (+/- 10 %) at 50/60 Hz","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...60 °C","Maximum [Up] voltage protection level":"Common mode Common mode <1.1 kV type 2 N/PE","[Uc] maximum continuous operating voltage":"Common mode: 350 V L/PE Common mode: 350 V N/PE"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$83.24","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/vn/en/product/A9L20200/iprd20-modular-surge-arrester-2p-350v/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9L20200/alternatives.json"},"ai":{"faq":[{"question":"What is A9L20200's listed depth and width?","answer":"Depth is 69 mm, width is 36 mm (2 modular pitches)."},{"question":"What compliance documentation does this brand provide for A9L20200?","answer":"The product carries NF and KEMA-KEUR quality labels and complies with EN 61643-11:2012 and IEC 61643-11:2011 standards."},{"question":"Where can I buy A9L20200 and how is it quoted?","answer":"The A9L20200 is sourced to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9L20200","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9L20200 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}