{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9MEM3250-NMI","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9MEM3250-NMI","canonicalUrl":"https://aoctrl.com/schneider/A9MEM3250-NMI","factsUrl":"https://aoctrl.com/api/mcp/products/A9MEM3250-NMI","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iEM3000 series, A9MEM3250-NMI, electronic energy meter, Class 0.5S active energy, 100...277 V / 173...480 V, 5 A or 1 A CT input, Modbus RTU, LCD display, DIN rail clip-on.","salesMarkdown":"The Schneider Electric A9MEM3250-NMI is an Acti9 iEM3250 electronic energy meter — a DIN-rail mounted, clip-on sub-metering device from the Acti9 iEM3000 series. It measures active energy, current, voltage, and active power for three-phase (3P, 3P+N) or single-phase (1P+N) circuits, with Class 0.5S accuracy on active energy per IEC 62053-22 and IEC 61557-12. Rated voltage covers 100...277 V (line-to-neutral) and 173...480 V (line-to-line), making it suitable for common low-voltage distribution in buildings, data centers, healthcare, and industrial sites. Current input is via external current transformers (CTs) rated 1 A or 5 A secondary. Clip-on DIN-rail mounting (per IEC 60715), 10 x 9 mm pitch modules wide (90 mm), 95 mm tall, 69 mm deep. The form factor fits standard distribution board space — a 10-module-wide slot is common for meters. Screw terminals: 6 mm² for the current circuit, 2.5 mm² for voltage. IP40 on the front panel (finger-safe behind the door), IP20 on the body. Operating altitude below 3000 m, ambient storage from -40 to 85 °C, and 5–95% relative humidity at 50 °C.","metaTitle":"Schneider Electric A9MEM3250-NMI Acti9 iEM3250 Energy Meter,","metaDescription":"Schneider Electric A9MEM3250-NMI Acti9 iEM3250 energy meter. Class 0.5S accuracy, Modbus RTU, 100-277 / 173-480 V, 5/1 A CT input. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Color":"White","Depth":"69 mm","Width":"90 mm","Height":"95 mm","Voltage":"100...277 V 173...480 V","Input Type":"Current transformer 1 A or 5 A","Application":"Sub billing Partial meter","Input Count":"0","Display Type":"LCD display","Output Count":"0","Product Status":"Active","Pollution Degree":"2","Temp Storage Max":"85 °C","Temp Storage Min":"-40 °C","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-40...85 °C","Main Product Or Component Type":"Energy meter","Ambient Air Temperature Operation":"-25...70 °C - IEC"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/au/en/product/A9MEM3250-NMI/iem3250-energy-meter-ct-modbus-nmi/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9MEM3250-NMI/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9MEM3250-NMI","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9MEM3250-NMI when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}