{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N16201","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N16201","canonicalUrl":"https://aoctrl.com/schneider/A9N16201","factsUrl":"https://aoctrl.com/api/mcp/products/A9N16201","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 xID RCCB, A9N16201, 2P, 25 A, 30 mA, Type AC, 230-240 V AC, 50 Hz, DIN rail.","salesMarkdown":"The Schneider Electric A9N16201 is an Acti9 xID residual current circuit breaker (RCCB) — a 2-pole device rated for 25 A continuous current with 30 mA earth-leakage sensitivity. The 30 mA threshold is the standard for personal protection against fatal electric shock in residential and commercial final circuits. Rated at 25 A (In) with a breaking capacity of 500 A per IEC 61008-1. The 30 mA sensitivity trips on leakage to ground, protecting personnel. Type AC covers sinusoidal residual currents — common for resistive and inductive loads without electronics. If the circuit feeds switched-mode power supplies, VFDs, or LED drivers that generate pulsed or DC fault currents, Type A or Type B RCCBs would be needed instead. The 2-pole (2P) configuration switches both phase and neutral. Rated insulation voltage (Ui) is 500 V AC, and the operational voltage range is 230-240 V AC — single-phase line-to-neutral supplies. Terminals accept 1-35 mm² rigid or 1-25 mm² flexible cable. The tunnel-type terminals allow daisy-chaining or looping through. IP20 rated — install inside an enclosure rated for the environment. Designed and tested to IEC 61008-1 and EN 61008-2-1 — the international and European standards for residual current operated circuit-breakers without integral overcurrent protection. The device is suitable for isolation (disconnector function) and has a contact position indicator showing ON, OFF, or fault trip. A padlocking device can lock it in the OFF position for safe maintenance.","metaTitle":"Schneider Electric A9N16201 Acti9 xID RCCB, 25 A, 30 mA, 2P","metaDescription":"Schneider Electric A9N16201 Acti9 xID residual current circuit breaker (RCCB). 25 A rated current, 30 mA sensitivity, 2P, Type AC, 230-240 V AC, 50 Hz. DIN rail mount. IEC 61008. A","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"75 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"81 mm","Standards":"IEC 61008-2-1 EN 61008-2-1 EN/IEC 61008-1","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 xID","Mounting mode":"Clip-on","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Connection pitch":"18 mm between phases","Local signalling":"ON, OFF, fault trip","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"2","Device short name":"xID","Network frequency":"50 Hz","Poles description":"2P","Relative humidity":"95 % at 55 °C","Tightening torque":"3.5 N.m top or bottom","[In] rated current":"25 A","Electrical durability":"4000 cycles","Mechanical durability":"4000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Tunnel type terminals (top or bottom) 1...35 mm² rigid Tunnel type terminals (top or bottom) 1...25 mm² flexible","IP degree of protection":"IP20","Earth-leakage sensitivity":"30 mA","Product or component type":"Residual current circuit breaker (RCCB)","Suitability for isolation":"Yes","Contact position indicator":"Yes","Locking options description":"Padlocking device","[Ui] rated insulation voltage":"500 V AC 50 Hz","Earth-leakage protection class":"Type AC","[Ue] rated operational voltage":"230...240 V AC 50 Hz","Rated breaking and making capacity":"500 A conforming to EN/IEC 61008-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Ambient air temperature for operation":"-5...40 °C","[Uimp] rated impulse withstand voltage":"6 kV","Comb busbar and distribution block compatibility":"Downside: biconnect"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9N16201/acti-9-xid-residual-circuit-breaker-25-a-2p-30ma-class-ac-instantaneous/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N16201/alternatives.json"},"ai":{"faq":[{"question":"What is A9N16201 used for?","answer":"The A9N16201 is a residual current circuit breaker (RCCB) used for earth-leakage protection in single-phase 230-240 V AC circuits. It trips at 30 mA leakage to protect against electric shock, and is installed on DIN rails in distribution boards for residential, commercial, and light industrial final circuits."},{"question":"What is the difference between Type AC and Type A RCCBs?","answer":"Type AC RCCBs (like this A9N16201) detect sinusoidal AC residual currents only. Type A RCCBs additionally detect pulsed DC residual currents, which are generated by electronics such as rectifiers, switching power supplies, and VFDs. For circuits with those loads, a Type A device is required to ensure the leakage is detected."},{"question":"Where can I buy A9N16201 and how is it quoted?","answer":"The A9N16201 is sourced and quoted to order against an RFQ through independent industrial-automation distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N16201","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N16201 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}