{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N16204","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N16204","canonicalUrl":"https://aoctrl.com/schneider/A9N16204","factsUrl":"https://aoctrl.com/api/mcp/products/A9N16204","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 xID RCCB, 2P, 40 A, 30 mA Type AC, 230-240 V AC, clip-on DIN rail.","salesMarkdown":"The Schneider Electric A9N16204 is an Acti9 xID residual current circuit breaker (RCCB) — a 2-pole, 40 A, 30 mA sensitivity Type AC device for 230-240 V AC 50 Hz networks. The 30 mA earth-leakage threshold is the standard for personal protection against indirect contact in residential and commercial final circuits; Type AC detection covers sinusoidal AC residual currents only. Neutral is on the left. The IP20 enclosure suits clean, dry indoor panels. Compliant with EN/IEC 61008-1 and EN/IEC 61008-2-1. Pollution degree 2. Storage temperature range -40 to 85 °C. Rated insulation voltage 500 V AC. Breaking and making capacity 500 A per IEC 61008-1. Electrical and mechanical durability each 4000 cycles.","metaTitle":"Schneider Electric A9N16204 Acti9 xID RCCB, 2P 40A 30mA Type","metaDescription":"Schneider Electric A9N16204 Acti9 xID RCCB, 2P 40A 30mA Type AC, 230-240V, clip-on DIN rail. Sourced to order against RFQ. Specifications per EN/IEC 61008-1.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"75 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"81 mm","Standards":"EN 61008-2-1 IEC 61008-2-1 EN/IEC 61008-1","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 xID","Mounting mode":"Clip-on","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Connection pitch":"18 mm between phases","Local signalling":"ON, OFF, fault trip","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"2","Device short name":"xID","Network frequency":"50 Hz","Poles description":"2P","Relative humidity":"95 % at 55 °C","Tightening torque":"3.5 N.m top or bottom","[In] rated current":"40 A","Electrical durability":"4000 cycles","Mechanical durability":"4000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Tunnel type terminals (top or bottom) 1...35 mm² rigid Tunnel type terminals (top or bottom) 1...25 mm² flexible","IP degree of protection":"IP20","Earth-leakage sensitivity":"30 mA","Product or component type":"Residual current circuit breaker (RCCB)","Suitability for isolation":"Yes","Contact position indicator":"Yes","Locking options description":"Padlocking device","[Ui] rated insulation voltage":"500 V AC 50 Hz","Earth-leakage protection class":"Type AC","[Ue] rated operational voltage":"230...240 V AC 50 Hz","Rated breaking and making capacity":"500 A conforming to EN/IEC 61008-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Ambient air temperature for operation":"-5...40 °C","[Uimp] rated impulse withstand voltage":"6 kV","Comb busbar and distribution block compatibility":"Downside: biconnect"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9N16204/acti-9-xid-residual-circuit-breaker-40-a-2p-30ma-class-ac-instantaneous/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N16204/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy A9N16204?","answer":"It is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What are the key ratings of A9N16204?","answer":"It is a 2-pole RCCB rated 40 A, 30 mA sensitivity Type AC, for 230-240 V AC 50 Hz, with a breaking capacity of 500 A per IEC 61008-1."},{"question":"What is the mounting and connection spec for A9N16204?","answer":"Clip-on DIN rail mount, 36 mm wide (4 x 9 mm pitches). Tunnel terminals accept 1-35 mm² rigid or 1-25 mm² flexible, strip length 14 mm, torque 3.5 N·m. Neutral left, IP20."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N16204","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N16204 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}