{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N16205","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N16205","canonicalUrl":"https://aoctrl.com/schneider/A9N16205","factsUrl":"https://aoctrl.com/api/mcp/products/A9N16205","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 xID RCCB, 2P, 40 A, 100 mA, Type AC, 230-240 V AC, DIN rail.","salesMarkdown":"The Schneider Electric A9N16205 is an Acti9 xID residual current circuit breaker (RCCB) — a 2-pole, Type AC device rated at 40 A with 100 mA earth-leakage sensitivity. The Type AC classification means it detects sinusoidal AC earth faults only, so it's suited for general-purpose circuits where no pulsed DC or mixed-frequency leakage is expected — think lighting, socket outlets, and resistive loads in commercial or residential distribution boards. The 40 A rated current (In) sets the continuous load this RCCB can carry without tripping on overload — sized for a 40 A submain or final circuit. The 100 mA sensitivity is less sensitive than the common 30 mA type; it's chosen where nuisance tripping from cable capacitance or equipment leakage is a concern, or where the installation standard allows a higher threshold (e.g., fire-protection RCCBs or circuits feeding fixed equipment). ## Integration notes Neutral is on the left — verify busbar orientation if linking to an adjacent MCB or RCCB. Tunnel terminals accept 1-35 mm² rigid or 1-25 mm² flexible; strip 14 mm, torque to 3.5 N·m. Padlocking provision allows lockout for isolation, and the toggle gives clear ON/OFF/trip indication.","metaTitle":"Schneider Electric A9N16205 Acti9 xID RCCB, 40 A, 100 mA, 2P","metaDescription":"Schneider Electric A9N16205 Acti9 xID RCCB, 40 A rated current, 100 mA earth-leakage sensitivity, Type AC, 2-pole, 230-240 V AC, DIN rail mount. Current production, sourced to orde","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"75 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"81 mm","Standards":"EN/IEC 61008-1 EN 61008-2-1 IEC 61008-2-1","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 xID","Mounting mode":"Clip-on","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Connection pitch":"18 mm between phases","Local signalling":"ON, OFF, fault trip","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"2","Device short name":"xID","Network frequency":"50 Hz","Poles description":"2P","Relative humidity":"95 % at 55 °C","Tightening torque":"3.5 N.m top or bottom","[In] rated current":"40 A","Electrical durability":"4000 cycles","Mechanical durability":"4000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Tunnel type terminals (top or bottom) 1...35 mm² rigid Tunnel type terminals (top or bottom) 1...25 mm² flexible","IP degree of protection":"IP20","Earth-leakage sensitivity":"100 mA","Product or component type":"Residual current circuit breaker (RCCB)","Suitability for isolation":"Yes","Contact position indicator":"Yes","Locking options description":"Padlocking device","[Ui] rated insulation voltage":"500 V AC 50 Hz","Earth-leakage protection class":"Type AC","[Ue] rated operational voltage":"230...240 V AC 50 Hz","Rated breaking and making capacity":"500 A conforming to EN/IEC 61008-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Ambient air temperature for operation":"-5...40 °C","[Uimp] rated impulse withstand voltage":"6 kV","Comb busbar and distribution block compatibility":"Downside: biconnect"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9N16205/acti-9-xid-residual-circuit-breaker-40-a-2p-100ma-class-ac-instantaneous/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N16205/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy the A9N16205 and how is it quoted?","answer":"The A9N16205 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What are the key ratings of the A9N16205?","answer":"The A9N16205 is a 2-pole Type AC RCCB rated at 40 A with 100 mA earth-leakage sensitivity, operating at 230-240 V AC, 50 Hz, with a 500 A breaking capacity per EN/IEC 61008-1."},{"question":"What compliance standards does the A9N16205 meet?","answer":"The A9N16205 complies with EN/IEC 61008-1, EN 61008-2-1, and IEC 61008-2-1. It is tropicalised to class 2 per IEC 60068-1."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N16205","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N16205 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}