{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N16209","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N16209","canonicalUrl":"https://aoctrl.com/schneider/A9N16209","factsUrl":"https://aoctrl.com/api/mcp/products/A9N16209","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 xID, Residual current circuit breaker (RCCB), 2P, 63 A, 100 mA Type AC, 230...240 V AC, clip-on DIN rail.","salesMarkdown":"The Schneider Electric A9N16209 is a 2-pole residual current circuit breaker (RCCB) from the Acti9 xID range, rated 63 A with 100 mA earth-leakage sensitivity, Type AC. It protects against sinusoidal AC fault currents in residential and commercial final circuits — the 100 mA threshold suits sub-distribution boards or circuits feeding equipment with some natural leakage, where a 30 mA device would nuisance-trip. The Type AC designation means it responds only to alternating residual currents, not pulsed DC or mixed-frequency faults, so it belongs in standard lighting, socket-outlet, or general-purpose AC circuits, not inverter-fed or EV-charger feeds. The instantaneous trip characteristic means no intentional delay; it clears the fault within the standard RCCB response time. Tunnel terminals accept 1...35 mm² rigid or 1...25 mm² flexible cable; wire stripping length is 14 mm. The 18 mm phase-to-phase pitch aligns with standard busbar systems in Acti9 distribution boards. The white housing carries local ON/OFF and fault-trip indication, plus a padlocking provision for lockout/tagout during maintenance. Designed and certified to EN 61008-2-1, EN/IEC 61008-1, and IEC 61008-2-1 — the core RCCB product standards covering operation, tripping accuracy, and endurance. Pollution degree 2 (non-conductive pollution only, occasional condensation) is the typical rating for protected indoor switchgear. Electrical and mechanical durability are both rated at 4000 cycles, which aligns with the expected service life of a distribution-board RCCB under normal switching and fault-clearing duty.","metaTitle":"Schneider Electric A9N16209 Acti9 xID RCCB, 63A 100mA Type A","metaDescription":"Schneider Electric A9N16209 Acti9 xID RCCB, 2P, 63A rated current, 100mA Type AC earth leakage, 230-240V AC, clip-on DIN rail. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"75 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"81 mm","Standards":"EN 61008-2-1 EN/IEC 61008-1 IEC 61008-2-1","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 xID","Mounting mode":"Clip-on","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Connection pitch":"18 mm between phases","Local signalling":"ON, OFF, fault trip","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"2","Device short name":"xID","Network frequency":"50 Hz","Poles description":"2P","Relative humidity":"95 % at 55 °C","Tightening torque":"3.5 N.m top or bottom","[In] rated current":"63 A","Electrical durability":"4000 cycles","Mechanical durability":"4000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Tunnel type terminals (top or bottom) 1...35 mm² rigid Tunnel type terminals (top or bottom) 1...25 mm² flexible","IP degree of protection":"IP20","Earth-leakage sensitivity":"100 mA","Product or component type":"Residual current circuit breaker (RCCB)","Suitability for isolation":"Yes","Contact position indicator":"Yes","Locking options description":"Padlocking device","[Ui] rated insulation voltage":"500 V AC 50 Hz","Earth-leakage protection class":"Type AC","[Ue] rated operational voltage":"230...240 V AC 50 Hz","Rated breaking and making capacity":"630 A conforming to EN/IEC 61008-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Ambient air temperature for operation":"-5...40 °C","[Uimp] rated impulse withstand voltage":"6 kV","Comb busbar and distribution block compatibility":"Downside: biconnect"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9N16209/acti-9-xid-residual-circuit-breaker-63-a-2p-100ma-class-ac-instantaneous/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N16209/alternatives.json"},"ai":{"faq":[{"question":"Who supplies A9N16209 and how is it quoted for volume purchases?","answer":"The A9N16209 is sourced through independent distribution channels and quoted to order against an RFQ; availability and current pricing are confirmed at quote time."},{"question":"What is A9N16209's listed depth?","answer":"The listed depth is 75 mm."},{"question":"What is A9N16209's listed range?","answer":"The range is Acti9, and the product name is Acti9 xID."},{"question":"What compliance documentation does this brand provide for A9N16209?","answer":"The A9N16209 is certified to EN 61008-2-1, EN/IEC 61008-1, and IEC 61008-2-1. It carries a pollution degree 2 rating and tropicalisation class 2 per IEC 60068-1."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N16209","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N16209 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}