{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N16210","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N16210","canonicalUrl":"https://aoctrl.com/schneider/A9N16210","factsUrl":"https://aoctrl.com/api/mcp/products/A9N16210","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 xID, residual current circuit breaker (RCCB), 2P, 63 A, 300 mA Type AC, 230-240 V AC, DIN rail clip-on, white.","salesMarkdown":"The Schneider Electric A9N16210 is a 2-pole residual current circuit breaker (RCCB) from the Acti9 xID range, rated 63 A with 300 mA earth-leakage sensitivity, Type AC. The 300 mA sensitivity suits general-purpose earth-leakage protection where a higher trip threshold avoids nuisance tripping from normal leakage in fixed equipment or long cable runs. Type AC detection responds to sinusoidal AC residual currents only. Rated 63 A continuous at 230-240 V AC, this RCCB handles the full load current of a typical main distribution board or submain feeding multiple final circuits. Insulation voltage rated 500 V AC gives headroom above the operating voltage, so the internal clearances and creepage distances are designed for that higher stress. Pollution degree 2 (non-conductive pollution only, occasional condensation) is the standard for enclosed electrical panels. Mechanical and electrical durability both rated 4000 cycles — this is a protection device, not a daily-switching contactor, so the cycle count reflects the expected life in a distribution board where it operates only on fault or periodic test. Wire stripping length 14 mm for top or bottom connection. The padlocking device allows locking in the OFF position for isolation during maintenance — the contact position indicator confirms the state visually. ## Standards and lifecycle Designed to IEC 61008-1 and EN 61008-2-1, the main standards for residual current circuit breakers without integral overcurrent protection. IP20 rated for finger-safe installation inside a panel enclosure. Tropicalisation level 2 per IEC 60068-1 for damp-heat environments.","metaTitle":"Schneider Electric A9N16210 Acti9 xID RCCB, 63 A, 300 mA, Ty","metaDescription":"Schneider Electric A9N16210 Acti9 xID 2P RCCB, 63 A rated current, 300 mA earth-leakage sensitivity, Type AC, 230-240 V AC, DIN rail mount. Active production. Quoted on request.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"75 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"81 mm","Standards":"IEC 61008-2-1 EN/IEC 61008-1 EN 61008-2-1","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 xID","Mounting mode":"Clip-on","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Connection pitch":"18 mm between phases","Local signalling":"ON, OFF, fault trip","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"2","Device short name":"xID","Network frequency":"50 Hz","Poles description":"2P","Relative humidity":"95 % at 55 °C","Tightening torque":"3.5 N.m top or bottom","[In] rated current":"63 A","Electrical durability":"4000 cycles","Mechanical durability":"4000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Tunnel type terminals (top or bottom) 1...35 mm² rigid Tunnel type terminals (top or bottom) 1...25 mm² flexible","IP degree of protection":"IP20","Earth-leakage sensitivity":"300 mA","Product or component type":"Residual current circuit breaker (RCCB)","Suitability for isolation":"Yes","Contact position indicator":"Yes","Locking options description":"Padlocking device","[Ui] rated insulation voltage":"500 V AC 50 Hz","Earth-leakage protection class":"Type AC","[Ue] rated operational voltage":"230...240 V AC 50 Hz","Rated breaking and making capacity":"630 A conforming to EN/IEC 61008-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Ambient air temperature for operation":"-5...40 °C","[Uimp] rated impulse withstand voltage":"6 kV","Comb busbar and distribution block compatibility":"Downside: biconnect"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9N16210/acti-9-xid-residual-circuit-breaker-63-a-2p-300ma-class-ac-instantaneous/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N16210/alternatives.json"},"ai":{"faq":[{"question":"What is A9N16210's listed depth (75 mm) on this component line?","answer":"The A9N16210 has a depth of 75 mm."},{"question":"What is A9N16210's listed range (Acti9) on this component line?","answer":"The A9N16210 belongs to the Acti9 range."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N16210","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N16210 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}