{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N16213","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N16213","canonicalUrl":"https://aoctrl.com/schneider/A9N16213","factsUrl":"https://aoctrl.com/api/mcp/products/A9N16213","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 xID RCCB, A9N16213, 2P, 80 A, 100 mA Type AC earth leakage, 230-240 V AC, DIN rail clip-on.","salesMarkdown":"The Schneider Electric A9N16213 is an Acti9 xID residual current circuit breaker (RCCB) — 2 poles, rated 80 A continuous, with 100 mA earth-leakage sensitivity, Type AC. The 230-240 V AC 50 Hz operational voltage and 800 A breaking capacity per EN/IEC 61008-1 mean it handles standard single-phase residential or light commercial sub-distribution. The instantaneous trip on AC sinusoidal fault currents gives fast disconnection for basic shock protection, but Type AC only detects sinusoidal residual currents — not pulsed DC or smooth DC waveforms that VFDs or switched-mode supplies can generate. Clip-on mounting to DIN rail, neutral on the left. Tunnel terminals accept up to 35 mm² rigid or 25 mm² flexible on top or bottom — wire stripping length 14 mm, tightening torque 3.5 N·m. The 18 mm phase-to-phase pitch matches standard Acti9 busbar spacing. IP20 rated, so it lives inside an enclosure, not in a washdown zone. Padlocking provision allows lockout/tagout for isolation duty (suitability for isolation is marked). Meets EN/IEC 61008-1 and EN 61008-2-1. Storage range -40 to 85 °C, 95 % RH at 55 °C. Electrical and mechanical durability both rated at 4000 cycles — consistent with a residential-duty RCCB, not a high-cycling industrial contactor.","metaTitle":"Schneider Electric A9N16213 Acti9 xID RCCB, 80A 100mA Type A","metaDescription":"Schneider Electric A9N16213 Acti9 xID RCCB, 80A rated current, 100mA earth leakage sensitivity, Type AC, 2P, 230-240V AC, DIN rail mount. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"75 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"81 mm","Standards":"EN/IEC 61008-1 EN 61008-2-1 IEC 61008-2-1","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 xID","Mounting mode":"Clip-on","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Connection pitch":"18 mm between phases","Local signalling":"ON, OFF, fault trip","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"2","Device short name":"xID","Network frequency":"50 Hz","Poles description":"2P","Relative humidity":"95 % at 55 °C","Tightening torque":"3.5 N.m top or bottom","[In] rated current":"80 A","Electrical durability":"4000 cycles","Mechanical durability":"4000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Tunnel type terminals (top or bottom) 1...35 mm² rigid Tunnel type terminals (top or bottom) 1...25 mm² flexible","IP degree of protection":"IP20","Earth-leakage sensitivity":"100 mA","Product or component type":"Residual current circuit breaker (RCCB)","Suitability for isolation":"Yes","Contact position indicator":"Yes","Locking options description":"Padlocking device","[Ui] rated insulation voltage":"500 V AC 50 Hz","Earth-leakage protection class":"Type AC","[Ue] rated operational voltage":"230...240 V AC 50 Hz","Rated breaking and making capacity":"800 A conforming to EN/IEC 61008-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Ambient air temperature for operation":"-5...40 °C","[Uimp] rated impulse withstand voltage":"6 kV","Comb busbar and distribution block compatibility":"Downside: biconnect"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9N16213/acti-9-xid-residual-circuit-breaker-80-a-2p-100ma-class-ac-instantaneous/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N16213/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy the A9N16213?","answer":"The A9N16213 is sourced and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time through independent distribution."},{"question":"What is the A9N16213 used for?","answer":"It is a 2-pole residual current circuit breaker (RCCB) for AC circuits, rated 80 A with 100 mA earth-leakage sensitivity. It provides disconnection on sinusoidal fault currents in residential or light commercial sub-distribution panels."},{"question":"What are the key ratings of the A9N16213?","answer":"Rated current 80 A, earth-leakage sensitivity 100 mA Type AC, operational voltage 230-240 V AC 50 Hz, breaking capacity 800 A per EN/IEC 61008-1, 2 poles, instantaneous trip."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N16213","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N16213 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}