{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N16214","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N16214","canonicalUrl":"https://aoctrl.com/schneider/A9N16214","factsUrl":"https://aoctrl.com/api/mcp/products/A9N16214","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 xID, Residual Current Circuit Breaker (RCCB), A9N16214, 80 A, 300 mA, 2P, Type AC, 230-240 V AC, clip-on DIN rail.","salesMarkdown":"The Schneider Electric A9N16214 is a 2-pole Residual Current Circuit Breaker (RCCB) from the Acti9 xID series, rated 80 A with 300 mA earth-leakage sensitivity. It protects against earth faults in AC circuits at 230-240 V, 50 Hz. The 300 mA trip threshold suits it for general distribution protection rather than personal shock protection — it's sized to catch insulation faults and prevent fire risk on submain or feeder circuits, not for socket-outlet final circuits where 30 mA is the norm. Neutral on the left. Tunnel terminals accept 1-35 mm² rigid or 1-25 mm² flexible cable; strip 14 mm and torque to 3.5 N.m. If the downstream load includes electronics with rectifiers, a Type A or Type B RCCB would be needed instead. Rated insulation voltage 500 V AC, operational voltage 230-240 V AC. The 80 A continuous rating and 4000-cycle electrical/mechanical durability are typical for a distribution RCCB in this form factor — it's not a heavy-duty switching device, but a protective device that trips infrequently under fault conditions.","metaTitle":"A9N16214 Acti9 xID RCCB 80A 300mA 2P Type AC","metaDescription":"Schneider Electric A9N16214 Acti9 xID RCCB, 80A rated current, 300mA earth leakage sensitivity, 2P, Type AC, 230-240V AC. Active production, sourced to order. Quoted on request.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"75 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"81 mm","Standards":"IEC 61008-2-1 EN/IEC 61008-1 EN 61008-2-1","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 xID","Mounting mode":"Clip-on","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Connection pitch":"18 mm between phases","Local signalling":"ON, OFF, fault trip","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"2","Device short name":"xID","Network frequency":"50 Hz","Poles description":"2P","Relative humidity":"95 % at 55 °C","Tightening torque":"3.5 N.m top or bottom","[In] rated current":"80 A","Electrical durability":"4000 cycles","Mechanical durability":"4000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Tunnel type terminals (top or bottom) 1...35 mm² rigid Tunnel type terminals (top or bottom) 1...25 mm² flexible","IP degree of protection":"IP20","Earth-leakage sensitivity":"300 mA","Product or component type":"Residual current circuit breaker (RCCB)","Suitability for isolation":"Yes","Contact position indicator":"Yes","Locking options description":"Padlocking device","[Ui] rated insulation voltage":"500 V AC 50 Hz","Earth-leakage protection class":"Type AC","[Ue] rated operational voltage":"230...240 V AC 50 Hz","Rated breaking and making capacity":"800 A conforming to EN/IEC 61008-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Ambient air temperature for operation":"-5...40 °C","[Uimp] rated impulse withstand voltage":"6 kV","Comb busbar and distribution block compatibility":"Downside: biconnect"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9N16214/acti-9-xid-residual-circuit-breaker-80-a-2p-300ma-class-ac-instantaneous/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N16214/alternatives.json"},"ai":{"faq":[{"question":"What is the earth-leakage sensitivity and protection class?","answer":"300 mA sensitivity, Type AC. This detects sinusoidal AC residual currents only. For circuits with non-sinusoidal or DC fault currents, a Type A or Type B device is required."},{"question":"Where can I buy A9N16214 and how is it quoted?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock figures or lead-time numbers are published here."},{"question":"What compliance documentation does this RCCB carry?","answer":"It complies with IEC 61008-1, IEC 61008-2-1, and EN 61008-2-1. Tropicalisation per IEC 60068-1. Pollution degree 2. Suitability for isolation is marked on the device."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N16214","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N16214 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}