{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N16260","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N16260","canonicalUrl":"https://aoctrl.com/schneider/A9N16260","factsUrl":"https://aoctrl.com/api/mcp/products/A9N16260","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 xID RCCB, A9N16260, 4P, 63 A, 300 mA Type AC, 400-415 V AC, DIN rail clip-on.","salesMarkdown":"The Schneider Electric A9N16260 is an Acti9 xID residual current circuit breaker (RCCB) — a 4-pole, 63 A unit with 300 mA earth-leakage sensitivity, Type AC, rated for 400-415 V AC at 50 Hz. The 300 mA sensitivity on this RCCB is not for personnel protection — that's the 30 mA job. This is sized for fire prevention and equipment protection on circuits with higher natural leakage, like long cable runs or industrial heaters. Same footprint, different internal sensing. Mounts on standard DIN rail via the clip-on mechanism. Neutral is on the left (fixed position). Tunnel terminals accept 1-35 mm² rigid or 1-25 mm² flexible cable; strip length is 14 mm, torque to 3.5 N·m. The 72 mm width (8 x 18 mm pitches) is a standard 4P RCCB footprint — it fits any Acti9 board without crowding adjacent ways. Lockable with a padlocking device for lockout/tagout. Rated breaking and making capacity is 630 A per EN/IEC 61008-1. Insulation voltage is 500 V AC. Pollution degree 2, tropicalisation class 2 per IEC 60068-1 (handles 95% RH at 55 °C). Electrical and mechanical durability are both rated at 4000 cycles. IP20 finger-safe terminals. Ambient storage range is -40 to 85 °C.","metaTitle":"Schneider Electric A9N16260 Acti9 xID RCCB, 63 A, 300 mA, 4P","metaDescription":"Schneider Electric A9N16260 Acti9 xID residual current circuit breaker (RCCB), 63 A rated current, 300 mA earth leakage sensitivity, 4-pole, Type AC, 400-415 V AC, DIN rail mount.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"75 mm","Range":"Acti9","Width":"72 mm","Colour":"White","Height":"81 mm","Standards":"EN 61008-2-1 IEC 61008-2-1 EN/IEC 61008-1","9 Mm Pitches":"8","Control type":"Toggle","Network type":"AC","Product name":"Acti9 xID","Mounting mode":"Clip-on","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Connection pitch":"18 mm between phases","Local signalling":"ON, OFF, fault trip","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"2","Device short name":"xID","Network frequency":"50 Hz","Poles description":"4P","Relative humidity":"95 % at 55 °C","Tightening torque":"3.5 N.m top or bottom","[In] rated current":"63 A","Electrical durability":"4000 cycles","Mechanical durability":"4000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Tunnel type terminals (top or bottom) 1...35 mm² rigid Tunnel type terminals (top or bottom) 1...25 mm² flexible","IP degree of protection":"IP20","Earth-leakage sensitivity":"300 mA","Product or component type":"Residual current circuit breaker (RCCB)","Suitability for isolation":"Yes","Contact position indicator":"Yes","Locking options description":"Padlocking device","[Ui] rated insulation voltage":"500 V AC 50 Hz","Earth-leakage protection class":"Type AC","[Ue] rated operational voltage":"400...415 V AC 50 Hz","Rated breaking and making capacity":"630 A conforming to EN/IEC 61008-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Ambient air temperature for operation":"-5...40 °C","[Uimp] rated impulse withstand voltage":"6 kV","Comb busbar and distribution block compatibility":"Downside: biconnect"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9N16260/acti-9-xid-residual-circuit-breaker-63-a-4p-300ma-class-ac-instantaneous/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N16260/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for the A9N16260?","answer":"Submit an RFQ through this listing. Pricing and lead time are confirmed at quote time through independent distribution channels."},{"question":"What is the closest alternative to the A9N16260 in the Acti9 family?","answer":"The closest alternative is the same Acti9 xID RCCB but with a different sensitivity or type — for example, a 30 mA Type A variant for personnel protection on circuits with pulsed DC loads. The mechanical footprint and wiring are identical; only the internal trip coil changes."},{"question":"What is the A9N16260's depth?","answer":"The depth is 75 mm."},{"question":"What compliance standards does the A9N16260 meet?","answer":"It conforms to EN 61008-2-1, IEC 61008-2-1, and EN/IEC 61008-1. Tropicalisation is class 2 per IEC 60068-1. IP20 rated."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N16260","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N16260 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}