{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N16261","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N16261","canonicalUrl":"https://aoctrl.com/schneider/A9N16261","factsUrl":"https://aoctrl.com/api/mcp/products/A9N16261","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 xID RCCB, 4P, 80 A, 30 mA, Type AC, 400-415 V AC, DIN rail.","salesMarkdown":"The Schneider Electric A9N16261 is a 4-pole residual current circuit breaker (RCCB) from the Acti9 xID range, rated at 80 A with 30 mA earth-leakage sensitivity — the standard threshold for personal protection against direct contact in residential and commercial final circuits. That makes it suitable for general-purpose circuits feeding resistive, inductive, or lighting loads where no rectified or pulsed DC fault currents are expected. Clip-on mounting onto a DIN rail, 18 mm phase-to-phase pitch, occupying 8 x 9 mm pitches — so 72 mm wide on the rail. Neutral on the left, tunnel terminals top and bottom accepting 1...35 mm² rigid or 1...25 mm² flexible, with a 3.5 N·m tightening torque and 14 mm strip length. The IP20 finger-safe terminals are fine for enclosed distribution boards; no washdown rating here, so keep it behind a gland plate or panel door. Padlocking provision for lockout/tagout on the toggle, with local ON/OFF/fault-trip indication on the face. 80 A rated current (In) governs the continuous load the RCCB can carry without tripping on thermal overload — sized for a 3-phase submain or a large single-phase final circuit. The 30 mA sensitivity is the IEC-recommended touch-protection threshold; it will trip on any earth fault exceeding that residual current, typically within 300 ms (instantaneous, no intentional delay). The 4000-cycle electrical and mechanical durability is standard for a switch-disconnect device in normal duty; not a high-endurance figure for frequent switching, but adequate for protection duty where the device operates only on fault or during testing.","metaTitle":"Schneider Electric A9N16261 Acti9 xID RCCB, 80 A, 30 mA, 4P","metaDescription":"Schneider Electric A9N16261 Acti9 xID RCCB. 80 A rated current, 30 mA earth leakage sensitivity, 4P, Type AC, 400-415 V AC. DIN rail mount. Current production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"75 mm","Range":"Acti9","Width":"72 mm","Colour":"White","Height":"81 mm","Standards":"EN/IEC 61008-1 EN 61008-2-1 IEC 61008-2-1","9 Mm Pitches":"8","Control type":"Toggle","Network type":"AC","Product name":"Acti9 xID","Mounting mode":"Clip-on","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Connection pitch":"18 mm between phases","Local signalling":"ON, OFF, fault trip","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"2","Device short name":"xID","Network frequency":"50 Hz","Poles description":"4P","Relative humidity":"95 % at 55 °C","Tightening torque":"3.5 N.m top or bottom","[In] rated current":"80 A","Electrical durability":"4000 cycles","Mechanical durability":"4000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Tunnel type terminals (top or bottom) 1...35 mm² rigid Tunnel type terminals (top or bottom) 1...25 mm² flexible","IP degree of protection":"IP20","Earth-leakage sensitivity":"30 mA","Product or component type":"Residual current circuit breaker (RCCB)","Suitability for isolation":"Yes","Contact position indicator":"Yes","Locking options description":"Padlocking device","[Ui] rated insulation voltage":"500 V AC 50 Hz","Earth-leakage protection class":"Type AC","[Ue] rated operational voltage":"400...415 V AC 50 Hz","Rated breaking and making capacity":"800 A conforming to EN/IEC 61008-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Ambient air temperature for operation":"-5...40 °C","[Uimp] rated impulse withstand voltage":"6 kV","Comb busbar and distribution block compatibility":"Downside: biconnect"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9N16261/acti-9-xid-residual-circuit-breaker-80-a-4p-30ma-class-ac-instantaneous/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N16261/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy the A9N16261 and get a price?","answer":"The A9N16261 is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."},{"question":"What is the A9N16261's earth leakage sensitivity and type?","answer":"30 mA Type AC — the standard personal-protection threshold for sinusoidal AC fault currents, suitable for general-purpose circuits without rectified or pulsed DC loads."},{"question":"What standards does the A9N16261 comply with?","answer":"EN/IEC 61008-1 and EN 61008-2-1 / IEC 61008-2-1 — the core standards for residual current circuit breakers without integral overcurrent protection."},{"question":"What is the A9N16261's rated breaking capacity?","answer":"800 A conforming to EN/IEC 61008-1 — adequate for sub-distribution board fault interruption, not a high-fault rating for main incomer duty."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N16261","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N16261 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}