{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N16263","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N16263","canonicalUrl":"https://aoctrl.com/schneider/A9N16263","factsUrl":"https://aoctrl.com/api/mcp/products/A9N16263","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 xID RCCB, 4P, 80 A, 300 mA Type AC, 400-415 V AC, clip-on DIN rail mount, IEC 61008-1.","salesMarkdown":"The Schneider Electric A9N16263 is an Acti9 xID residual current circuit breaker (RCCB) — a 4-pole, Type AC device rated for 80 A continuous current with 300 mA earth-leakage sensitivity. It operates on 400-415 V AC, 50 Hz networks and clips onto a DIN rail for panel mounting. The 300 mA sensitivity is the standard threshold for general-purpose socket-outlet and lighting circuits in commercial and industrial distribution boards, providing personnel protection against indirect contact while avoiding nuisance tripping on small leakage currents typical of permanently connected equipment. Mounts via clip-on to DIN rail — 72 mm wide, 81 mm tall, 75 mm deep. The 4-pole unit occupies 8 module pitches (9 mm each) on the rail. Neutral is on the left. Tunnel-type terminals accept 1-35 mm² rigid or 1-25 mm² flexible cable; tighten to 3.5 N·m top or bottom. Rated breaking and making capacity is 800 A conforming to EN/IEC 61008-1 — sufficient for clearing downstream faults in a residential or light commercial distribution board. Electrical and mechanical durability are both rated at 4000 cycles. The device is suitable for isolation (visible contact gap), with a contact position indicator and padlocking provision. Pollution degree 2 for normal industrial environments.","metaTitle":"Schneider Electric A9N16263 Acti9 xID RCCB, 80 A, 300 mA, 4P","metaDescription":"Schneider Electric A9N16263 Acti9 xID RCCB, 80 A rated current, 300 mA sensitivity, 4P, Type AC, 400-415 V AC, IEC 61008-1. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"75 mm","Range":"Acti9","Width":"72 mm","Colour":"White","Height":"81 mm","Standards":"IEC 61008-2-1 EN 61008-2-1 EN/IEC 61008-1","9 Mm Pitches":"8","Control type":"Toggle","Network type":"AC","Product name":"Acti9 xID","Mounting mode":"Clip-on","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Connection pitch":"18 mm between phases","Local signalling":"ON, OFF, fault trip","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"2","Device short name":"xID","Network frequency":"50 Hz","Poles description":"4P","Relative humidity":"95 % at 55 °C","Tightening torque":"3.5 N.m top or bottom","[In] rated current":"80 A","Electrical durability":"4000 cycles","Mechanical durability":"4000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Tunnel type terminals (top or bottom) 1...35 mm² rigid Tunnel type terminals (top or bottom) 1...25 mm² flexible","IP degree of protection":"IP20","Earth-leakage sensitivity":"300 mA","Product or component type":"Residual current circuit breaker (RCCB)","Suitability for isolation":"Yes","Contact position indicator":"Yes","Locking options description":"Padlocking device","[Ui] rated insulation voltage":"500 V AC 50 Hz","Earth-leakage protection class":"Type AC","[Ue] rated operational voltage":"400...415 V AC 50 Hz","Rated breaking and making capacity":"800 A conforming to EN/IEC 61008-1","Ambient air temperature for storage":"-40...85 °C","Earth-leakage protection time delay":"Instantaneous","Ambient air temperature for operation":"-5...40 °C","[Uimp] rated impulse withstand voltage":"6 kV","Comb busbar and distribution block compatibility":"Downside: biconnect"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9N16263/acti-9-xid-residual-circuit-breaker-80-a-4p-300ma-class-ac-instantaneous/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N16263/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for A9N16263?","answer":"80 A rated current, 300 mA earth-leakage sensitivity, Type AC, 4-pole, rated operational voltage 400-415 V AC at 50 Hz, breaking capacity 800 A per IEC 61008-1."},{"question":"Where can I buy A9N16263 and how is it quoted?","answer":"Sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at the time of quotation."},{"question":"What standards does A9N16263 comply with?","answer":"Compliant with IEC 61008-2-1, EN 61008-2-1, and EN/IEC 61008-1. Tropicalisation per IEC 60068-1 class 2."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N16263","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N16263 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}