{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N18346","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N18346","canonicalUrl":"https://aoctrl.com/schneider/A9N18346","factsUrl":"https://aoctrl.com/api/mcp/products/A9N18346","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 C120, miniature circuit breaker, 100 A, B curve, 2P, 10 kA Icn at 400 V AC, clip-on DIN rail.","salesMarkdown":"The Schneider Electric A9N18346 is a 100 A rated miniature circuit breaker from the Acti9 C120 series, 2-pole, B-curve, with a 10 kA Icn breaking capacity at 400 V AC. Rated 10 kA Icn at 400 V AC per EN/IEC 60898-1, and 6 kA Icu at 440 V AC per EN/IEC 60947-2. It also carries 10 kA Icu at 220-240 V and 380-415 V AC under the industrial standard. Dual-rated to both the household (60898-1) and industrial (60947-2) standards, so it qualifies for distribution boards and industrial panel applications alike. Tunnel terminals accept 1-50 mm² rigid or 1.5-35 mm² flexible, with a 3.5 N·m tightening torque and 15 mm strip length. Neutral position is left; toggle control with ON/OFF local indication.","metaTitle":"Schneider Electric A9N18346 Acti9 C120 MCB, 100A B Curve 2P,","metaDescription":"Schneider Electric A9N18346 Acti9 C120 miniature circuit breaker, 100A rated, B curve, 2-pole, 10kA breaking capacity at 400V AC. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Color":"White","Depth":"73 mm","Width":"54 mm","Height":"81 mm","Voltage":"380...415 V AC 50/60 Hz 220...240 V AC 50/60 Hz 440 V AC 50/60 Hz 230...400 V AC 50/60 Hz","IP Rating":"IP20","Application":"Distribution","Control Type":"Toggle","Product Status":"Active","Trip Unit Type":"Thermal-magnetic","Pollution Degree":"3 conforming to IEC 60947-2","Temp Storage Max":"85 °C","Temp Storage Min":"-40 °C","Breaking Capacity":"10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2","Insulation Voltage Ui":"500 V AC 50/60 Hz conforming to EN/IEC 60947-2","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-40...85 °C","Electrical Life Cycles":"5000 cycles conforming to IEC 60947-2","Mechanical Life Cycles":"20000 cycles","Main Product Or Component Type":"Miniature circuit-breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e0f068e95f5332cec00d7e43ccee3c70.pdf","sourceUrl":"https://www.se.com/ie/en/product/A9N18346/miniature-circuit-breaker-mcb-acti9-c120n-2p-100a-b-curve-10000a-iec-en-608981-10ka-iec-en-609472/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N18346/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N18346","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N18346 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}