{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N18378","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N18378","canonicalUrl":"https://aoctrl.com/schneider/A9N18378","factsUrl":"https://aoctrl.com/api/mcp/products/A9N18378","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 C120N miniature circuit-breaker, A9N18378, 1P, D-curve, 63 A rated current, 10 kA Icn, clip-on 35 mm DIN rail.","salesMarkdown":"The Schneider Electric A9N18378 is a 1-pole miniature circuit-breaker from the Acti9 C120 range, rated 63 A at 30 °C with a D tripping curve. The D-curve magnetic trip fires at 10 to 14 times the rated current, so it avoids nuisance tripping on inductive loads while still clearing a hard fault. Rated Icn is 10000 A at 230/400 V AC per EN/IEC 60898-1, and the Icu per EN/IEC 60947-2 reaches 10 kA at 220...240 V AC and 3 kA at 380...415 V AC (IT system). That dual-rating means the breaker can serve both residential-style final circuits (60898-1) and industrial panel feeders (60947-2) — a single part number covers both compliance paths. Occupies 27 mm width (3 x 9 mm pitches) on the DIN rail. Tunnel terminals accept 1...50 mm² rigid or 1.5...35 mm² flexible; strip length 15 mm, tighten to 3.5 N.m. The toggle gives local ON/OFF indication and a contact position indicator confirms isolation status per IEC 60947-2.","metaTitle":"Schneider Electric A9N18378 Acti9 C120N MCB, 1P D 63 A, 10 k","metaDescription":"Schneider Electric A9N18378 Acti9 C120N miniature circuit-breaker, 1P, D-curve, 63 A, 10 kA Icn. Sourced to order against RFQ. EN/IEC 60898-1 & 60947-2.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Color":"White","Depth":"73 mm","Width":"27 mm","Height":"81 mm","Voltage":"380...415 V AC 50/60 Hz 125 V DC 12 V DC 220...240 V AC 50/60 Hz 230...400 V AC 50/60 Hz 130 V AC 50/60 Hz 12 V AC 50/60 Hz","IP Rating":"IP20","Application":"Distribution","Control Type":"Toggle","Product Status":"Active","Trip Unit Type":"Thermal-magnetic","Pollution Degree":"3 conforming to IEC 60947-2","Temp Storage Max":"85 °C","Temp Storage Min":"-40 °C","Insulation Voltage Ui":"500 V AC 50/60 Hz conforming to EN/IEC 60947-2","Temp Operating Max":"70 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-40...85 °C","Electrical Life Cycles":"10000 cycles conforming to IEC 60947-2","Mechanical Life Cycles":"20000 cycles","Main Product Or Component Type":"Miniature circuit-breaker","Ambient Air Temperature Operation":"-25...70 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/8366a95bae0ba3f6d19ffc771ba31a46.pdf","sourceUrl":"https://www.se.com/ae/en/product/A9N18378/c120n-circuit-breaker-1p-63a-d-curve/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N18378/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N18378","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N18378 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}