{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N18480","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N18480","canonicalUrl":"https://aoctrl.com/schneider/A9N18480","factsUrl":"https://aoctrl.com/api/mcp/products/A9N18480","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 C120H series, miniature circuit breaker, 100A, 4-pole, C-curve, breaking capacity 15 kA Icn at 400 V AC.","salesMarkdown":"The A9N18480: Clips onto 35 mm symmetrical DIN rail. Tunnel terminals: 1…50 mm² rigid, 1.5…35 mm² flexible. Strip 15 mm, torque to 3.5 N·m. IP20, pollution degree 3, 2000 m altitude. Magnetic trip 5…10 x In. Standalone earth-leakage protection via separate block. Current production. Available through standard distribution; no LTB or EOL notice. RFQ for firm lead time and quantity pricing.","metaTitle":"Schneider Electric A9N18480 Acti9 C120H MCB, 100A 4P C-Curve","metaDescription":"A9N18480 Acti9 C120H miniature circuit breaker, 100A 4-pole C-curve, 15 kA Icn at 400V AC. Active production, sourced to order. RFQ for lead time.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"73 mm","Range":"Acti9","Width":"108 mm","Colour":"White","Height":"81 mm","Standards":"EN/IEC 60898-1 EN/IEC 60947-2","Curve code":"C","9 Mm Pitches":"12","Control type":"Toggle","Network type":"AC","Product name":"Acti9 C120","Mounting mode":"Clip-on","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60947-2","Local signalling":"ON/OFF indication","Mounting support":"35 mm symmetrical DIN rail","Pollution degree":"3 conforming to IEC 60947-2","Breaking capacity":"15000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at <= 500 V DC conforming to EN/IEC 60947-2","Device short name":"C120H","Network frequency":"50/60 Hz","Poles description":"4P","Relative humidity":"95 % at 55 °C","Tightening torque":"3.5 N.m","Device application":"Distribution","Operating altitude":"2000 m","[In] rated current":"100 A at 30 °C","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Electrical durability":"5000 cycles conforming to IEC 60947-2","Mechanical durability":"20000 cycles","Wire stripping length":"15 mm","Connections - terminals":"Tunnel type terminals1...50 mm² rigid Tunnel type terminals1.5...35 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Separate block","Number of protected poles":"4","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to IEC 60947-2","Contact position indicator":"Yes","Locking options description":"Handle sealable with cable diameter 0.7mm in OFF or ON position","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to EN/IEC 60947-2","[Ue] rated operational voltage":"380...415 V AC 50/60 Hz 220...240 V AC 50/60 Hz 440 V AC 50/60 Hz 230...400 V AC 50/60 Hz","Ambient air temperature for storage":"-40...70 °C","Ambient air temperature for operation":"-30...60 °C","[Ics] rated service breaking capacity":"7500 A 50 % conforming to EN/IEC 60898-1 - 400 V AC 50/60 Hz 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 15 kA 50 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - <= 500 V DC","[Uimp] rated impulse withstand voltage":"6 kV conforming to EN/IEC 60947-2","Comb busbar and distribution block compatibility":"NO"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$154.94","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b5ea48012460152b62420acff58ea4f9.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N18480/alternatives.json"},"ai":{"faq":[{"question":"What is the depth of this component?","answer":"73 mm."},{"question":"What is the Acti9 range?","answer":"This MCB belongs to the Acti9 range from Schneider Electric."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N18480","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N18480 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}