{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N18545","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N18545","canonicalUrl":"https://aoctrl.com/schneider/A9N18545","factsUrl":"https://aoctrl.com/api/mcp/products/A9N18545","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Vigi C120, A9N18545, add-on residual current device, 2P, 125A, AC type, selective, 1000mA, 230...415V AC.","salesMarkdown":"Rated 125 A at 230...415 V AC, it provides 1000 mA AC-type residual current protection with a selective (time-delayed) trip characteristic, meaning it coordinates downstream so only the faulted branch clears first. The 125 A rated current (In) matches high-current outgoing feeders or incomer positions in distribution boards. The 1000 mA sensitivity is a selective (delayed) trip — it's not for personnel protection (which requires 30 mA) but for equipment-level earth-fault protection with coordination downstream. AC-type detection handles sinusoidal residual currents only; if your loads include rectifiers, VFDs, or switched-mode supplies, you'd need Type A or Type B instead. The 230...415 V AC operational voltage covers single-phase and three-phase networks up to 415 V phase-to-phase. Electrical connection to the MCB is by screws (tunnel terminals accepting 1...35 mm² flexible or 1...50 mm² rigid). The 2-pole (2P) format fits single-phase or two-wire circuits.","metaTitle":"Schneider Electric A9N18545 Vigi C120 RCD, 2P 125A 1000mA AC","metaDescription":"Schneider Electric A9N18545 Acti9 Vigi C120 add-on RCD, 2P, 125A, 1000mA AC type, selective. Obsolete — sourced to order. Request quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Color":"White","Depth":"73 mm","Width":"117 mm","Height":"95 mm","Voltage":"230...415 V AC 50/60 Hz","IP Rating":"IP20","Product Status":"Active","Pollution Degree":"3 conforming to IEC 60947-2","Temp Storage Max":"60 °C","Temp Storage Min":"-40 °C","Insulation Voltage Ui":"500 V AC 50/60 Hz conforming to IEC 60947-1","Temp Operating Max":"60 °C","Temp Operating Min":"-5 °C","Temperature Storage":"-40...60 °C","Mechanical Life Cycles":"20000 cycles","Main Product Or Component Type":"Add-on residual current device","Ambient Air Temperature Operation":"-5...60 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/07b668e9fae38ba115c9cde508c0a911.pdf","sourceUrl":"https://www.se.com/ie/en/product/A9N18545/addon-residual-current-device-acti9-vigi-c120-2p-125a-ac-type-selective-1000ma-230-415vac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N18545/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N18545","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N18545 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}