{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N18549","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N18549","canonicalUrl":"https://aoctrl.com/schneider/A9N18549","factsUrl":"https://aoctrl.com/api/mcp/products/A9N18549","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Vigi C120 add-on residual current device, 4P, 125 A, Type AC selective, 1000 mA, 230...415 V AC, clip-on 35 mm DIN rail.","salesMarkdown":"The A9N18549 is a 4-pole add-on residual current device from the Acti9 Vigi C120 range, rated 125 A with a 1000 mA earth-leakage sensitivity. The 125 A rated current (In) sets the continuous load this RCD can carry without derating — sized for a main feeder or large sub-feed in a 230...415 V AC network. The 1000 mA sensitivity is selective (time-delayed), meaning it coordinates with downstream 30 mA or 300 mA RCDs so that a fault on a branch trips the branch device first, not this upstream unit. That selectivity is critical in a distribution board where you want nuisance-free coordination. Type AC earth-leakage protection covers sinusoidal AC residual currents only — standard for general-purpose circuits without electronic loads that generate pulsed or DC fault currents. The voltage-independent tripping technology means the RCD operates even if the supply neutral is lost, a reliability feature for safety continuity. Clip-on mounting on 35 mm DIN rail, 4-pole wide at 198 mm (10 x 9 mm pitches). Tunnel terminals accept 1...50 mm² rigid or 1...35 mm² flexible cable; tighten to 3.5 N.m. Strip 15 mm of insulation. IP20 finger-safe terminals — standard for enclosed distribution boards.","metaTitle":"A9N18549 Acti9 Vigi C120 4P 125A RCD, 1000mA Type AC Selecti","metaDescription":"A9N18549 Acti9 Vigi C120 add-on RCD, 4P, 125A, 1000mA Type AC selective, 230-415V AC. Active production. Sourced to order. Quoted on request.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Color":"White","Depth":"73 mm","Width":"198 mm","Height":"95 mm","Voltage":"230...415 V AC 50/60 Hz","IP Rating":"IP20","Product Status":"Active","Pollution Degree":"3 conforming to IEC 60947-2","Temp Storage Max":"60 °C","Temp Storage Min":"-40 °C","Insulation Voltage Ui":"500 V AC 50/60 Hz conforming to IEC 60947-1","Temp Operating Max":"60 °C","Temp Operating Min":"-5 °C","Temperature Storage":"-40...60 °C","Mechanical Life Cycles":"20000 cycles","Main Product Or Component Type":"Add-on residual current device","Ambient Air Temperature Operation":"-5...60 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c7566fa1b49162f4d80bac62f4ff4378.pdf","sourceUrl":"https://www.se.com/id/en/product/A9N18549/addon-residual-current-device-acti9-vigi-c120-4p-125a-ac-type-selective-1000ma-230-415vac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N18549/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N18549","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N18549 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}