{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N18555","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N18555","canonicalUrl":"https://aoctrl.com/schneider/A9N18555","factsUrl":"https://aoctrl.com/api/mcp/products/A9N18555","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Vigi C120, add-on residual current device, 4P, 125 A, Type A-SI, 300 mA, instantaneous, 230...415 V AC, clip-on 35 mm DIN rail.","salesMarkdown":"The A9N18555 is an add-on residual current device (RCD) from the Acti9 Vigi C120 series, designed to bolt onto the line side of a compatible Acti9 MCB via screw terminals. It is rated for 125 A continuous current on a 4-pole (4P) AC network at 230...415 V, 50 Hz. The 300 mA earth-leakage sensitivity with Type A-SI (Super Immunised) classification means it handles pulsed DC fault currents and resists nuisance tripping from high-frequency harmonics — common on VFD-fed or UPS-backed circuits. The instantaneous time delay clears faults without intentional lag, so coordination with downstream RCDs needs a check on selectivity. The voltage-independent tripping technology means the device does not need an external power supply to open on a residual fault — it uses the fault current itself to energise the trip solenoid. That makes it inherently fail-safe on a lost neutral or phase dropout, which matters for circuits where continuity of protection is critical. The 198 mm width across 10 x 9 mm pitches means it occupies ten modular spaces in the enclosure — plan the DIN rail fill factor accordingly. Tunnel-type terminals accept 1...50 mm² rigid or 1...35 mm² flexible cable; strip length is 15 mm, tighten to 3.5 N·m. The screw connection to the adjacent MCB is a mechanical and electrical link — no extra busbar needed, but the MCB must be from the same Acti9 C120 family. IP20 finger protection on the terminals; the device is intended for enclosed panel installation, not open washdown areas.","metaTitle":"Schneider Electric A9N18555 Acti9 Vigi C120, 4P 125A RCD, Ty","metaDescription":"Schneider Electric A9N18555 Acti9 Vigi C120 add-on RCD, 4P, 125A, Type A-SI, 300mA, instantaneous. Active lifecycle. Sourced to order. Quoted on request.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Color":"White","Depth":"73 mm","Width":"198 mm","Height":"95 mm","Voltage":"230...415 V AC 50 Hz","IP Rating":"IP20","Product Status":"Active","Pollution Degree":"3 conforming to IEC 60947-2","Temp Storage Max":"60 °C","Temp Storage Min":"-40 °C","Insulation Voltage Ui":"500 V AC 50/60 Hz conforming to IEC 60947-1","Temp Operating Max":"60 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-40...60 °C","Mechanical Life Cycles":"20000 cycles","Main Product Or Component Type":"Add-on residual current device","Ambient Air Temperature Operation":"-25...60 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/57aef05494197c8e9245488a3b8c9559.pdf","sourceUrl":"https://www.se.com/ie/en/product/A9N18555/addon-residual-current-device-acti9-vigi-c120-4p-125a-asi-type-instantaneous-300ma-230-415vac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N18555/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N18555","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N18555 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}