{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N18560","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N18560","canonicalUrl":"https://aoctrl.com/schneider/A9N18560","factsUrl":"https://aoctrl.com/api/mcp/products/A9N18560","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 Vigi C120 add-on residual current device, 4P, 125 A, 300 mA, Type A-SI, selective, 230…415 VAC, clip-on DIN rail.","salesMarkdown":"The A9N18560 is an add-on residual current device (RCD) from the Schneider Electric Acti9 Vigi C120 range, designed to clip onto the outgoing side of a compatible MCB or MCCB to provide earth-leakage protection. It is rated for 125 A continuous current with a 300 mA Type A-SI (Super Immunised) sensitivity and a selective (time-delayed) trip characteristic, making it suitable for downstream coordination in distribution boards where nuisance tripping from transient leakage must be avoided. The 125 A rated current sets the maximum continuous load this RCD can carry — sized for a main incomer or large subfeed in a commercial or industrial panel. The 300 mA sensitivity is above the 30 mA required for personal shock protection; this unit is intended for fire protection and equipment protection, not direct personnel protection. The Type A-SI classification means it detects sinusoidal AC and pulsating DC residual currents, and the 'Super Immunised' suffix indicates a higher immunity to high-frequency leakage from VFDs or UPS systems — a common source of nuisance trips in modern panels. The selective time delay allows coordination with downstream 30 mA RCDs, so only the faulted branch trips first. The 4P (4-pole) form factor occupies 10 x 9 mm pitches, so 90 mm of DIN rail width. Tunnel-type terminals accept 1…35 mm² flexible or 1…50 mm² rigid cable; strip length 15 mm, tighten to 3.5 N·m. IP20 finger-safe for enclosed panel use only.","metaTitle":"Schneider Electric A9N18560 Acti9 Vigi C120 RCD, 4P 125A 300","metaDescription":"Schneider Electric A9N18560 Acti9 Vigi C120 add-on residual current device, 4P, 125 A rated current, 300 mA Type A-SI, selective, active production, clip-on DIN rail mount.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Color":"White","Depth":"73 mm","Width":"198 mm","Height":"95 mm","Voltage":"230...415 V AC 50 Hz","IP Rating":"IP20","Product Status":"Active","Pollution Degree":"3 conforming to IEC 60947-2","Temp Storage Max":"60 °C","Temp Storage Min":"-40 °C","Insulation Voltage Ui":"500 V AC 50/60 Hz conforming to IEC 60947-1","Temp Operating Max":"60 °C","Temp Operating Min":"-25 °C","Temperature Storage":"-40...60 °C","Mechanical Life Cycles":"20000 cycles","Main Product Or Component Type":"Add-on residual current device","Ambient Air Temperature Operation":"-25...60 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/75abc5f261b2c53bc89f4e46dc5537cb.pdf","sourceUrl":"https://www.se.com/ie/en/product/A9N18560/addon-residual-current-device-acti9-vigi-c120-4p-125a-asi-type-selective-300ma-230-415vac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N18560/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N18560","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N18560 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}