{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N19633","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N19633","canonicalUrl":"https://aoctrl.com/schneider/A9N19633","factsUrl":"https://aoctrl.com/api/mcp/products/A9N19633","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9, DPN Vigi RCBO, Type A-SI (Super Immunised), 1P+N, 13 A, C-curve, 30 mA earth leakage, 6000 A Icn.","salesMarkdown":"## What the A9N19633 Is and Why It Matters It integrates a 13 A thermal-magnetic circuit breaker (C-curve, 5...10 x In magnetic trip) with a 30 mA residual current device, Type A-SI (Super Immunised). The Super Immunised designation means the RCD element is designed to resist nuisance tripping from high-frequency harmonics or pulsed DC waveforms common on modern electronic loads — switched-mode power supplies, variable-speed drives, and LED drivers — without compromising personnel protection. This is the key differentiator from a standard Type A RCBO. Rated 13 A at 30 °C, this RCBO protects a single outgoing circuit — typically lighting, general-purpose sockets, or small control loads. The 30 mA earth-leakage sensitivity provides personnel protection (shock) and fire protection for the circuit. Mounts on DIN rail and occupies 4 x 9 mm pitch modules — a compact 36 mm footprint for a 1P+N RCBO. Neutral is on the left. The toggle control provides local ON/OFF indication. Rated for ambient storage from -40 to 60 °C and operates at altitudes up to 2000 m.","metaTitle":"Schneider Electric A9N19633 Acti9 DPN Vigi RCBO, 13 A, 30 mA","metaDescription":"Schneider Electric A9N19633 Acti9 DPN Vigi RCBO, 13 A rated, 30 mA earth leakage, C-curve, Type A-SI (Super Immunised). 6000 A breaking capacity. DIN rail mount. Available to order","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Type":"Type A-SI (Super Immunised)","Range":"Acti9","Colour":"White","Standards":"EN/IEC 61009-2-1 EN/IEC 61009-1","Curve code":"C","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"DPN Vigi","Embedding depth":"72 mm","Tropicalisation":"2 conforming to EN 61009","lifecycle_stage":"current","Limitation class":"3 conforming to EN 61009","Local signalling":"ON/OFF indication","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3 conforming to EN 61009","Breaking capacity":"6000 A Icn at 230 V AC conforming to EN 61009","Device short name":"DPN N Vigi","Network frequency":"50/60 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Operating altitude":"2000 m","[In] rated current":"13 A at 30 °C","Overvoltage category":"III","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles conforming to IEC 61009","Mechanical durability":"20000 cycles","Connections - terminals":"Tunnel type terminals1 cable(s) 10 mm² flexible Tunnel type terminals1 cable(s) 16 mm² rigid","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Number of protected poles":"1","Product or component type":"Earth leakage circuit breaker","Contact position indicator":"Yes","Circuit breaker application":"Distribution","[Ui] rated insulation voltage":"400 V AC conforming to EN 61009","[Ue] rated operational voltage":"230 V AC 50/60 Hz","Ambient air temperature for storage":"-40...60 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"6000 A at 230 V AC 50/60 Hz conforming to EN 61009","[Uimp] rated impulse withstand voltage":"4 kV conforming to EN 61009"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/562c6ce36f906e8812a2ed620e8e8a05.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9N19633/acti9-earth-leakage-circuit-breaker-dpn-n-vigi-1p-+-n-13a-30ma/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N19633/alternatives.json"},"ai":{"faq":[{"question":"What does Type A-SI (Super Immunised) mean on this RCBO?","answer":"Type A-SI (Super Immunised) means the residual current device is designed to resist nuisance tripping from high-frequency leakage currents and pulsed DC waveforms generated by modern electronic loads like VFDs, SMPS, and LED drivers, while still providing personnel protection against sinusoidal AC and pulsating DC fault currents."},{"question":"What is the breaking capacity of the A9N19633?","answer":"The breaking capacity is 6000 A Icn at 230 V AC, certified to EN 61009."},{"question":"Where can I buy the A9N19633 and how is it quoted?","answer":"The A9N19633 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N19633","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N19633 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}