{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N19636","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N19636","canonicalUrl":"https://aoctrl.com/schneider/A9N19636","factsUrl":"https://aoctrl.com/api/mcp/products/A9N19636","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 DPN Vigi RCBO, Type A-SI (Super Immunised), 1P+N, 25 A, 30 mA, C curve, 6 kA Icn.","salesMarkdown":"The Type A-SI (Super Immunised) designation means the earth-leakage detection circuit is hardened against nuisance tripping from high-frequency harmonics, pulsed DC waveforms, and transient surges common on variable-speed drives, UPS systems, and LED lighting — loads that would trip a standard Type A device. The 30 mA sensitivity provides supplementary protection against electric shock for personnel, while the C-curve magnetic trip (5–10 x In) handles moderate inrush from motor and lighting circuits without nuisance trips. Rated current is 25 A at 30 °C, and the breaking capacity is 6000 A Icn at 230 V AC, conforming to EN/IEC 61009. The tunnel-type terminals accept 1…16 mm² rigid or 1…10 mm² flexible with ferrule; strip length is 15 mm and tightening torque is 2 N·m. For a panel OEM or MRO planner, this means the RCBO fits a standard 4-module cutout and terminates with standard screw-clamp wiring.","metaTitle":"Schneider Electric A9N19636 Acti9 DPN Vigi RCBO, Type A-SI,","metaDescription":"Schneider Electric A9N19636 Acti9 DPN Vigi RCBO, Type A-SI (Super Immunised), 25 A rated current, 30 mA earth-leakage sensitivity, C curve, 6 kA breaking capacity. Current producti","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Type":"Type A-SI (Super Immunised)","Depth":"77.5 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"81 mm","Standards":"EN/IEC 61009-1 EN/IEC 61009-2-1","Curve code":"C","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"DPN Vigi","Embedding depth":"44 mm","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN 61009","Local signalling":"ON/OFF indication","Mounting support":"35 mm DIN rail","Neutral position":"Left","Pollution degree":"3 conforming to EN 61009","Breaking capacity":"6000 A Icn at 230 V AC conforming to EN 61009","Device short name":"DPN N Vigi","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Operating altitude":"2000 m","[In] rated current":"25 A at 30 °C","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A","Electrical durability":"10000 cycles conforming to IEC 61009","Mechanical durability":"20000 cycles","Wire stripping length":"15 mm for top or bottom connection","Connections - terminals":"Tunnel type terminals (top or bottom) 1 cable(s) 1...10 mm² flexible with ferrule Tunnel type terminals (top or bottom) 1 cable(s) 1...16 mm² rigid","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Number of protected poles":"1","Product or component type":"Earth leakage circuit breaker","Contact position indicator":"Yes","Circuit breaker application":"Distribution","[Ui] rated insulation voltage":"400 V AC conforming to EN 61009","[Ue] rated operational voltage":"230 V AC","Ambient air temperature for storage":"-30...70 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"6000 A at 230 V AC 50/60 Hz conforming to EN 61009","[Uimp] rated impulse withstand voltage":"4 kV conforming to EN 61009"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/79b2d65c3ec04b456cd426cb32dc88b5.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9N19636/residual-current-breaker-with-overcurrent-protection-rcbo-acti9-dpn-n-vigi-1p+n-25a-30ma-asi-type-6000a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N19636/alternatives.json"},"ai":{"faq":[{"question":"What is the closest alternative to A9N19636 in the Acti9 range?","answer":"The evidence does not list a direct pin-compatible alternative. The A9N19636 is a specific Type A-SI (Super Immunised) RCBO with 25 A rating, 30 mA sensitivity, and C curve. A parametric search within the Acti9 DPN Vigi family for the same poles, sensitivity, curve, and current rating would yield the same part. No second-source cross-reference is recorded."},{"question":"What is A9N19636's Type A-SI (Super Immunised) rating?","answer":"Type A-SI (Super Immunised) means the earth-leakage detection is immune to nuisance tripping from pulsed DC, harmonics, and transient surges — suitable for circuits with VFDs, UPS, or LED drivers where standard Type A devices would false-trip."},{"question":"Where can I buy A9N19636?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N19636","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N19636 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}