{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N19650","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N19650","canonicalUrl":"https://aoctrl.com/schneider/A9N19650","factsUrl":"https://aoctrl.com/api/mcp/products/A9N19650","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 DPN Vigi RCBO, Type AC, 1P+N, 4 A, B curve, 30 mA sensitivity, 6 kA Icn at 230 V AC.","salesMarkdown":"The Schneider Electric A9N19650 is a DPN Vigi earth leakage circuit breaker from the Acti9 range, combining overcurrent and residual current protection in a single 1P+N module. Rated 4 A at 30 °C with a Type B tripping curve and 30 mA earth leakage sensitivity, it covers the common residential and light commercial distribution outgoer where both short-circuit and ground-fault protection are needed on a single pole. The 6 kA Icn breaking capacity at 230 V AC (EN 61009) is the standard domestic and light commercial fault-interruption level across most of Europe and Asia — adequate for final subcircuits where the prospective short-circuit current stays under that threshold. The 4 A rating and B curve (magnetic trip 3–5 × In) suit lighting and general-purpose socket circuits with low inrush; a C curve would be needed for motor or transformer loads. The 30 mA residual sensitivity is the standard for personal protection against indirect contact (EN 61008/61009). For circuits with variable-speed drives, LED drivers, or EV chargers that generate non-sinusoidal leakage, a Type A or Type F RCD would be required. Snaps onto DIN rail (EN 60715) and occupies 4 × 9 mm pitches — 36 mm wide. The 1P+N format switches the phase and switches the neutral without overcurrent protection on the neutral pole, which is standard for single-phase final circuits in many markets. Tunnel terminals accept up to 16 mm² rigid or 10 mm² flexible cable, enough for a 4 A outgoer with voltage drop margins.","metaTitle":"Schneider Electric A9N19650 DPN Vigi RCBO, 4 A Type B, 30 mA","metaDescription":"Schneider Electric A9N19650 DPN Vigi RCBO, 4 A rated current, Type B curve, 30 mA earth leakage, 6 kA breaking capacity at 230 V AC. Active lifecycle, sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Type":"Type AC","Range":"Acti9","Colour":"White","Standards":"EN/IEC 61009-2-1 EN/IEC 61009-1","Curve code":"B","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"DPN Vigi","Tropicalisation":"2 conforming to EN 61009","lifecycle_stage":"current","Limitation class":"3 conforming to EN 61009","Local signalling":"ON/OFF indication","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3 conforming to EN 61009","Breaking capacity":"6000 A Icn at 230 V AC 50/60 Hz conforming to EN 61009","Device short name":"DPN N Vigi","Network frequency":"50/60 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Operating altitude":"2000 m","[In] rated current":"4 A at 30 °C","Overvoltage category":"III","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles conforming to IEC 61009","Mechanical durability":"20000 cycles","Connections - terminals":"Tunnel type terminals1 cable(s) 10 mm² flexible Tunnel type terminals1 cable(s) 16 mm² rigid","Magnetic tripping limit":"3...5 x In","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Number of protected poles":"1","Product or component type":"Earth leakage circuit breaker","Contact position indicator":"Yes","Circuit breaker application":"Distribution","[Ui] rated insulation voltage":"400 V AC conforming to EN 61009","[Ue] rated operational voltage":"230 V AC 50/60 Hz","Ambient air temperature for storage":"-40...60 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-5...60 °C","[Ics] rated service breaking capacity":"6000 A at 230 V AC 50/60 Hz conforming to EN 61009","[Uimp] rated impulse withstand voltage":"4 kV conforming to EN 61009"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/9f7b3a3b20487c7619d0e7caa1f524b7.pdf","sourceUrl":"https://www.se.com/vn/en/product/A9N19650/acti9-earth-leakage-circuit-breaker-dpn-n-vigi-1p-+-n-4a-30ma/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N19650/alternatives.json"},"ai":{"faq":[{"question":"What is A9N19650's listed type (Type AC) on this component line?","answer":"The A9N19650 is a Type AC residual current device, meaning it detects sinusoidal AC earth faults only."},{"question":"What is A9N19650's listed range (Acti9) on this component line?","answer":"The A9N19650 belongs to the Schneider Acti9 range, a modular DIN-rail system for final distribution."},{"question":"Where can I buy A9N19650?","answer":"Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N19650","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N19650 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}