{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N19653","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N19653","canonicalUrl":"https://aoctrl.com/schneider/A9N19653","factsUrl":"https://aoctrl.com/api/mcp/products/A9N19653","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 DPN Vigi, Type AC RCBO, 1P+N, 10 A, B curve, 30 mA, 6 kA, white.","salesMarkdown":"The Schneider Electric A9N19653 is a DPN Vigi RCBO (residual current circuit breaker with overcurrent protection) from the Acti9 range, combining a 10 A thermal-magnetic MCB with integrated 30 mA earth-leakage protection in a single 1P+N module. Type AC detection means it trips on sinusoidal AC residual currents only — the standard choice for general-purpose socket and lighting circuits where no pulsed or DC fault currents are expected. Rated at 10 A (In) with a B-curve magnetic trip of 3 to 5 × In, so it clears short-circuit faults between 30 A and 50 A — well matched to final circuits with resistive or lightly inductive loads where nuisance tripping from inrush is a concern. The 30 mA residual sensitivity provides personal protection against indirect contact per IEC 60364. ## Deployment context Occupies 4 × 9 mm pitches (36 mm) for the 1P+N configuration — the neutral is on the left, and the outgoing terminal accepts up to 16 mm² rigid or 10 mm² flexible cable.","metaTitle":"Schneider Electric A9N19653 DPN Vigi 10A Type AC RCBO, 30mA,","metaDescription":"Schneider Electric A9N19653 DPN Vigi RCBO, 10A rated, 30mA sensitivity, Type AC, B curve, 6kA breaking capacity. Current production, available to order. Request a quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Type":"Type AC","Range":"Acti9","Colour":"White","Standards":"EN/IEC 61009-2-1 EN/IEC 61009-1","Curve code":"B","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"DPN Vigi","Tropicalisation":"2 conforming to EN 61009","lifecycle_stage":"current","Limitation class":"3 conforming to EN 61009","Local signalling":"ON/OFF indication","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3 conforming to EN 61009","Breaking capacity":"6000 A Icn at 230 V AC 50/60 Hz conforming to EN 61009","Device short name":"DPN N Vigi","Network frequency":"50/60 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Operating altitude":"2000 m","[In] rated current":"10 A at 30 °C","Overvoltage category":"III","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles conforming to IEC 61009","Mechanical durability":"20000 cycles","Connections - terminals":"Tunnel type terminals1 cable(s) 10 mm² flexible Tunnel type terminals1 cable(s) 16 mm² rigid","Magnetic tripping limit":"3...5 x In","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Number of protected poles":"1","Product or component type":"Earth leakage circuit breaker","Contact position indicator":"Yes","Circuit breaker application":"Distribution","[Ui] rated insulation voltage":"400 V AC conforming to EN 61009","[Ue] rated operational voltage":"230 V AC 50/60 Hz","Ambient air temperature for storage":"-40...60 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-5...60 °C","[Ics] rated service breaking capacity":"6000 A at 230 V AC 50/60 Hz conforming to EN 61009","[Uimp] rated impulse withstand voltage":"4 kV conforming to EN 61009"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/5f54bc5730671b63483790dd6662a4f4.pdf","sourceUrl":"https://www.se.com/vn/en/product/A9N19653/acti9-earth-leakage-circuit-breaker-dpn-n-vigi-1p-+-n-10a-30ma/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N19653/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy A9N19653 and how do I get a price?","answer":"The A9N19653 is sourced and quoted to order against an RFQ through independent distribution. Submit a request for quote to confirm current availability and pricing."},{"question":"What is A9N19653's listed type (Type AC) on this component line?","answer":"The A9N19653 is listed as Type AC, meaning it detects sinusoidal AC residual currents only. It is the standard choice for general-purpose circuits where no pulsed or DC fault currents are present."},{"question":"What is A9N19653's listed range (Acti9) on this component line?","answer":"The A9N19653 belongs to the Schneider Electric Acti9 range, a modular system of DIN-rail mounted protection devices for residential and commercial distribution boards."},{"question":"What compliance documentation does this brand provide for A9N19653 (RoHS, REACH, UL, IEC)?","answer":"The A9N19653 is certified to EN/IEC 61009-1 and EN/IEC 61009-2-1. For RoHS, REACH, and other regulatory documentation, refer to the manufacturer's compliance resources — these are typically available through the Schneider Electric product documentation portal."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N19653","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N19653 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}