{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N19657","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N19657","canonicalUrl":"https://aoctrl.com/schneider/A9N19657","factsUrl":"https://aoctrl.com/api/mcp/products/A9N19657","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 DPN Vigi RCBO, Type AC, 1P+N, 25 A, 30 mA, B curve, 6 kA, DIN rail.","salesMarkdown":"The Schneider Electric A9N19657 is a DPN Vigi residual-current circuit breaker (RCBO) from the Acti9 range, combining overcurrent protection and earth-leakage detection in a single 1P+N module. Rated at 25 A (In) with a B-curve magnetic trip (3–5 × In), it is sized for resistive and light inductive loads such as lighting circuits, socket outlets, and small appliances in residential or commercial distribution boards. The 30 mA earth-leakage sensitivity provides personal protection against indirect contact and additional fire protection per IEC 60364. Breaking capacity is 6 kA Icn at 230 V AC, 50/60 Hz, conforming to EN/IEC 61009-1 and 61009-2-1. Occupies 4 modules of 9 mm pitch — 36 mm total width for the 1P+N pole configuration. Neutral is on the left; the toggle switch provides local ON/OFF indication. Tunnel-type terminals accept up to 10 mm² flexible or 16 mm² rigid cable, one conductor per terminal. Operating altitude is limited to 2000 m; derating applies above that. Standards compliance includes EN/IEC 61009-1 and 61009-2-1. The device carries tropicalisation class 2 per EN 61009 and limitation class 3. Ambient storage range is -40 to 60 °C; relative humidity tolerance is 95 % at 55 °C.","metaTitle":"Schneider Electric A9N19657 DPN Vigi RCBO, Type AC, 25 A, 30","metaDescription":"Schneider Electric A9N19657 DPN Vigi RCBO, Type AC, 25 A rated, 30 mA earth leakage, B curve, 6 kA breaking capacity. Current production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Type":"Type AC","Range":"Acti9","Colour":"White","Standards":"EN/IEC 61009-2-1 EN/IEC 61009-1","Curve code":"B","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"DPN Vigi","Tropicalisation":"2 conforming to EN 61009","lifecycle_stage":"current","Limitation class":"3 conforming to EN 61009","Local signalling":"ON/OFF indication","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3 conforming to EN 61009","Breaking capacity":"6000 A Icn at 230 V AC 50/60 Hz conforming to EN 61009","Device short name":"DPN N Vigi","Network frequency":"50/60 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Operating altitude":"2000 m","[In] rated current":"25 A at 30 °C","Overvoltage category":"III","Trip unit technology":"Thermal-magnetic","Electrical durability":"10000 cycles conforming to IEC 61009","Mechanical durability":"20000 cycles","Connections - terminals":"Tunnel type terminals1 cable(s) 10 mm² flexible Tunnel type terminals1 cable(s) 16 mm² rigid","Magnetic tripping limit":"3...5 x In","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Number of protected poles":"1","Product or component type":"Earth leakage circuit breaker","Contact position indicator":"Yes","Circuit breaker application":"Distribution","[Ui] rated insulation voltage":"400 V AC conforming to EN 61009","[Ue] rated operational voltage":"230 V AC 50/60 Hz","Ambient air temperature for storage":"-40...60 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-5...60 °C","[Ics] rated service breaking capacity":"6000 A at 230 V AC 50/60 Hz conforming to EN 61009","[Uimp] rated impulse withstand voltage":"4 kV conforming to EN 61009"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/cd606ffe8fe5dc3979d70a6cda936c7a.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9N19657/acti9-earth-leakage-circuit-breaker-dpn-n-vigi-1p-+-n-25a-30ma/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N19657/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy the A9N19657 and get a price?","answer":"The A9N19657 is sourced through the authorized distribution channel. Submit an RFQ for current pricing and availability — each quote is confirmed at time of request with full factory traceability and warranty."},{"question":"What is the A9N19657's earth-leakage type?","answer":"It is a Type AC device, meaning it detects sinusoidal AC residual currents only. This is the standard type for general-purpose circuits without electronic loads or DC components."},{"question":"What is the A9N19657's rated current and sensitivity?","answer":"Rated current is 25 A (In) with a B-curve magnetic trip (3–5 × In). Earth-leakage sensitivity is 30 mA, providing personal protection against indirect contact."},{"question":"What compliance documentation does Schneider provide for the A9N19657?","answer":"The device is certified to EN/IEC 61009-1 and 61009-2-1. Full compliance documentation including declaration of conformity is available through the authorized channel upon request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N19657","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N19657 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}