{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N19658","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N19658","canonicalUrl":"https://aoctrl.com/schneider/A9N19658","factsUrl":"https://aoctrl.com/api/mcp/products/A9N19658","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 DPN Vigi RCBO, Type AC, B-curve, 32 A rated current, 30 mA earth-leakage sensitivity, 6 kA breaking capacity at 230 V AC, 1P+N, DIN-rail mount.","salesMarkdown":"It integrates a B-curve thermal-magnetic trip for overcurrent protection and a Type AC residual-current device (30 mA sensitivity) for earth-leakage detection, all in a 4-module (36 mm) DIN-rail footprint. This is the part you spec when a distribution board needs both MCB and RCD functions in one slot, saving panel space and wiring time. The Type AC residual-current detection handles sinusoidal AC earth faults only — not pulsed DC or smooth DC, so it is not suitable for circuits with VFDs, UPS outputs, or EV chargers that generate DC leakage. The tunnel-type terminals accept up to 16 mm² rigid or 10 mm² flexible cable — enough for a 32 A circuit on standard 4 mm² or 6 mm² copper. The toggle gives local ON/OFF indication, and the contact position indicator confirms the state even when the toggle is ambiguous. The device location is marked as outgoer — it feeds the load, not the busbar. The 4-module width (36 mm at 9 mm pitch) means it occupies four positions on the rail; plan your busbar comb and neutral bar accordingly. The operating altitude limit of 2000 m covers most sites; above that, derate the breaking capacity.","metaTitle":"Schneider Electric A9N19658 DPN Vigi RCBO, Type AC, B-Curve,","metaDescription":"Schneider Electric A9N19658 DPN Vigi RCBO, Type AC earth-leakage protection, B-curve, 32 A, 30 mA sensitivity, 6 kA breaking capacity. Active production, sourced to order against R","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Type":"Type AC","Range":"Acti9","Colour":"White","Standards":"EN/IEC 61009-1 EN/IEC 61009-2-1","Curve code":"B","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"DPN Vigi","Tropicalisation":"2 conforming to EN 61009","lifecycle_stage":"current","Limitation class":"3 conforming to EN 61009","Local signalling":"ON/OFF indication","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3 conforming to EN 61009","Breaking capacity":"6000 A Icn at 230 V AC 50/60 Hz conforming to EN 61009","Device short name":"DPN N Vigi","Network frequency":"50/60 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Operating altitude":"2000 m","[In] rated current":"32 A at 30 °C","Overvoltage category":"III","Trip unit technology":"Thermal-magnetic","Electrical durability":"10000 cycles conforming to IEC 61009","Mechanical durability":"20000 cycles","Connections - terminals":"Tunnel type terminals1 cable(s) 10 mm² flexible Tunnel type terminals1 cable(s) 16 mm² rigid","Magnetic tripping limit":"3...5 x In","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Number of protected poles":"1","Product or component type":"Earth leakage circuit breaker","Contact position indicator":"Yes","Circuit breaker application":"Distribution","[Ui] rated insulation voltage":"400 V AC conforming to EN 61009","[Ue] rated operational voltage":"230 V AC 50/60 Hz","Ambient air temperature for storage":"-40...60 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-5...60 °C","[Ics] rated service breaking capacity":"6000 A at 230 V AC 50/60 Hz conforming to EN 61009","[Uimp] rated impulse withstand voltage":"4 kV conforming to EN 61009"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a92a9c9a0b2c2f20a469fdd0e96f30f2.pdf","sourceUrl":"https://www.se.com/th/en/product/A9N19658/acti9-earth-leakage-circuit-breaker-dpn-n-vigi-1p-+-n-32a-30ma/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N19658/alternatives.json"},"ai":{"faq":[{"question":"What is A9N19658's Type AC rating?","answer":"Type AC means the residual-current device detects sinusoidal AC earth faults only. It is the standard type for circuits without non-sinusoidal or DC leakage — suitable for general-purpose socket outlets, lighting, and resistive loads."},{"question":"What standards does A9N19658 comply with?","answer":"It complies with EN/IEC 61009-1 and EN/IEC 61009-2-1, the harmonized standards for RCBOs (residual current operated circuit breakers with integral overcurrent protection)."},{"question":"Where can I buy A9N19658?","answer":"This part is sourced through independent distribution and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commitment."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N19658","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N19658 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}