{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N19661","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N19661","canonicalUrl":"https://aoctrl.com/schneider/A9N19661","factsUrl":"https://aoctrl.com/api/mcp/products/A9N19661","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 DPN N Vigi RCBO, Type AC, 1P+N, 6 A C-curve, 30 mA, 6 kA Icn at 230 V AC, DIN rail.","salesMarkdown":"The Schneider Electric A9N19661 is an Acti9 DPN N Vigi residual current circuit breaker with overcurrent protection (RCBO), combining a 6 A C-curve MCB and a 30 mA Type AC RCD in a single 1P+N module. It is rated for 230 V AC networks and breaks fault currents up to 6000 A Icn at that voltage, per EN/IEC 61009. The 6 A C-curve thermal-magnetic trip unit protects final sub-circuits with resistive and moderate inductive loads — think lighting banks, small fan coils, or socket outlets feeding office equipment. The C-curve magnetic release operates between 5 and 10 times In, so a 6 A unit trips instantaneously between 30 A and 60 A, which avoids nuisance trips from modest inrush while still clearing hard faults. ## Integration and deployment The residual current tripping is voltage-independent — it will operate even if the neutral is lost upstream, a key safety advantage over electronic RCDs.","metaTitle":"Schneider Electric A9N19661 DPN Vigi RCBO, 6A C-curve 30mA T","metaDescription":"Schneider Electric A9N19661 Acti9 DPN N Vigi RCBO. 6 A rated, C-curve, 30 mA Type AC residual current, 6 kA breaking capacity. DIN rail mount. Current production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Type":"Type AC","Range":"Acti9","Colour":"White","Standards":"EN/IEC 61009-1 EN/IEC 61009-2-1","Curve code":"C","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"DPN Vigi","Tropicalisation":"2 conforming to EN 61009","lifecycle_stage":"current","Limitation class":"3 conforming to EN 61009","Local signalling":"ON/OFF indication","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3 conforming to EN 61009","Breaking capacity":"6000 A Icn at 230 V AC conforming to EN 61009","Device short name":"DPN N Vigi","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Operating altitude":"2000 m","[In] rated current":"6 A at 30 °C","Overvoltage category":"III","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles conforming to IEC 61009","Mechanical durability":"20000 cycles","Connections - terminals":"Tunnel type terminals1 cable(s) 10 mm² flexible Tunnel type terminals1 cable(s) 16 mm² rigid","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Number of protected poles":"1","Product or component type":"Earth leakage circuit breaker","Contact position indicator":"Yes","Circuit breaker application":"Distribution","[Ui] rated insulation voltage":"400 V AC conforming to EN 61009","[Ue] rated operational voltage":"230 V AC","Ambient air temperature for storage":"-40...60 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-5...60 °C","[Ics] rated service breaking capacity":"6000 A at 230 V AC 50/60 Hz conforming to EN 61009","[Uimp] rated impulse withstand voltage":"4 kV conforming to EN 61009"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d68ac94c34be660383940b5ebba04db8.pdf","sourceUrl":"https://www.se.com/th/en/product/A9N19661/residual-current-breaker-with-overcurrent-protection-rcbo-acti9-dpn-n-vigi-1p+n-6a-30ma-ac-type-6000a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N19661/alternatives.json"},"ai":{"faq":[{"question":"What is the closest alternative to A9N19661 in the Acti9 range?","answer":"The closest sibling is the standard DPN N Vigi without the 'Type AC' suffix — functionally identical except for the residual current detection waveform. The A9N19661 is Type AC (sinusoidal AC only); the Type A variant (A9N19662) adds detection of pulsed DC residual currents, which is needed for circuits supplying single-phase electronics, LED drivers, or EV chargers. Both share the same 6 A C-curve, 30 mA sensitivity, 6 kA breaking capacity, and 1P+N form factor."},{"question":"How do I get pricing and availability for A9N19661?","answer":"Submit an RFQ through this listing. We source the A9N19661 through independent distribution channels and confirm current pricing and availability at quote time — no automated stock figure can reflect real-time supply."},{"question":"What compliance documentation does Schneider provide for A9N19661?","answer":"The A9N19661 is certified to EN/IEC 61009-1 and EN/IEC 61009-2-1, the harmonized standards for RCBOs. The tropicalisation treatment meets 2 classes per EN 61009, and the limitation class is 3. Standard Schneider documentation includes a CE declaration of conformity and the product datasheet; RoHS and REACH compliance statements are available on request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N19661","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N19661 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}