{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N19663","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N19663","canonicalUrl":"https://aoctrl.com/schneider/A9N19663","factsUrl":"https://aoctrl.com/api/mcp/products/A9N19663","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 DPN N Vigi RCBO, Type AC, 10 A, C-curve, 30 mA earth leakage, 1P+N, 6 kA Icn at 230 V AC.","salesMarkdown":"The Schneider Electric A9N19663 is an Acti9 DPN N Vigi residual current circuit breaker with overcurrent protection (RCBO), combining a 10 A C-curve thermal-magnetic trip with integrated 30 mA Type AC earth-leakage detection in a single 1P+N module. It's a current-production part, so no lifecycle hunting — this is the active catalog number for a distribution-board outgoing circuit needing both overcurrent and earth-fault protection in one DIN-rail slot. For industrial panels with higher fault levels, step up to a 10 kA or 15 kA rated device. Rated 10 A at 30 °C ambient, this RCBO handles a continuous load of about 2.3 kW on a 230 V single-phase circuit. The thermal-magnetic trip unit is voltage-independent for the overcurrent element, while the residual current detection is also voltage-independent per the spec — meaning it maintains earth-leakage protection even if the neutral is lost upstream. Neutral is on the left, phase on the right — wire it in that order to keep the internal neutral disconnect aligned. The 2000 m operating altitude covers most sites without derating. It carries full EN/IEC 61009-1 and 61009-2-1 certification, which is the harmonized standard for RCBOs in the EU. Rated for 20,000 electrical and 20,000 mechanical cycles — that's the endurance for a distribution board that sees regular switching, not a daily-use switch. The ON/OFF indicator and contact position indicator give a visual confirmation of state without needing to meter the load side.","metaTitle":"Schneider Electric A9N19663 DPN N Vigi RCBO, 10A C-Curve 30m","metaDescription":"Schneider Electric A9N19663 Acti9 DPN N Vigi RCBO, 10A rated, C-curve, 30mA Type AC earth leakage, 6kA breaking capacity. Current production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Type":"Type AC","Range":"Acti9","Colour":"White","Standards":"EN/IEC 61009-1 EN/IEC 61009-2-1","Curve code":"C","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"DPN Vigi","Tropicalisation":"2 conforming to EN 61009","lifecycle_stage":"current","Limitation class":"3 conforming to EN 61009","Local signalling":"ON/OFF indication","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3 conforming to EN 61009","Breaking capacity":"6000 A Icn at 230 V AC conforming to EN 61009","Device short name":"DPN N Vigi","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Operating altitude":"2000 m","[In] rated current":"10 A at 30 °C","Overvoltage category":"III","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles conforming to IEC 61009","Mechanical durability":"20000 cycles","Connections - terminals":"Tunnel type terminals1 cable(s) 10 mm² flexible Tunnel type terminals1 cable(s) 16 mm² rigid","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Number of protected poles":"1","Product or component type":"Earth leakage circuit breaker","Contact position indicator":"Yes","Circuit breaker application":"Distribution","[Ui] rated insulation voltage":"400 V AC conforming to EN 61009","[Ue] rated operational voltage":"230 V AC","Ambient air temperature for storage":"-40...60 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-5...60 °C","[Ics] rated service breaking capacity":"6000 A at 230 V AC 50/60 Hz conforming to EN 61009","[Uimp] rated impulse withstand voltage":"4 kV conforming to EN 61009"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/cd9c715e4f507e443abdca43d32ec19e.pdf","sourceUrl":"https://www.se.com/za/en/product/A9N19663/acti9-earth-leakage-circuit-breaker-dpn-n-vigi-1p-+-n-10a-30ma/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N19663/alternatives.json"},"ai":{"faq":[{"question":"What is the A9N19663's earth leakage sensitivity and type?","answer":"30 mA, Type AC — sinusoidal AC residual currents only. Standard for socket-outlet and general lighting circuits; not suitable for loads with rectified or pulsed DC fault currents."},{"question":"Where can I buy the A9N19663?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is the breaking capacity of this RCBO?","answer":"6 kA Icn at 230 V AC per EN 61009, which covers the prospective short-circuit current at most domestic and light commercial distribution boards in IEC markets."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N19663","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N19663 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}