{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N19666","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N19666","canonicalUrl":"https://aoctrl.com/schneider/A9N19666","factsUrl":"https://aoctrl.com/api/mcp/products/A9N19666","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 DPN N Vigi, RCBO, 1P+N, 20 A, 30 mA, Type AC, C-curve, 6 kA Icn at 230 V AC, DIN rail.","salesMarkdown":"It combines a 20 A thermal-magnetic trip (C-curve, 5...10 x In magnetic threshold) with integrated 30 mA Type AC earth-leakage detection in a single 4-module (9 mm pitch) DIN-rail unit. Mounts on DIN rail with neutral on the left side. The toggle provides local ON/OFF indication, and the contact position indicator confirms the state of the main contacts without needing to open the panel. The voltage-independent residual current trip operates instantaneously at 30 mA sensitivity, providing supplementary protection against direct contact. Electrical and mechanical durability are both rated at 20,000 cycles per IEC 61009.","metaTitle":"Schneider Electric A9N19666 DPN N Vigi RCBO, 20 A, 30 mA, Ty","metaDescription":"Schneider Electric A9N19666 DPN N Vigi RCBO. 20 A rated, 30 mA earth leakage, Type AC, C-curve, 6 kA breaking capacity. Current production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Type":"Type AC","Range":"Acti9","Colour":"White","Standards":"EN/IEC 61009-1 EN/IEC 61009-2-1","Curve code":"C","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"DPN Vigi","Tropicalisation":"2 conforming to EN 61009","lifecycle_stage":"current","Limitation class":"3 conforming to EN 61009","Local signalling":"ON/OFF indication","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3 conforming to EN 61009","Breaking capacity":"6000 A Icn at 230 V AC conforming to EN 61009","Device short name":"DPN N Vigi","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Operating altitude":"2000 m","[In] rated current":"20 A at 30 °C","Overvoltage category":"III","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles conforming to IEC 61009","Mechanical durability":"20000 cycles","Connections - terminals":"Tunnel type terminals1 cable(s) 10 mm² flexible Tunnel type terminals1 cable(s) 16 mm² rigid","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Number of protected poles":"1","Product or component type":"Earth leakage circuit breaker","Contact position indicator":"Yes","Circuit breaker application":"Distribution","[Ui] rated insulation voltage":"400 V AC conforming to EN 61009","[Ue] rated operational voltage":"230 V AC","Ambient air temperature for storage":"-40...60 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-5...60 °C","[Ics] rated service breaking capacity":"6000 A at 230 V AC 50/60 Hz conforming to EN 61009","[Uimp] rated impulse withstand voltage":"4 kV conforming to EN 61009"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$70.06","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/1c897e9ec7dd99809ccc967095734992.pdf","sourceUrl":"https://www.se.com/za/en/product/A9N19666/acti9-earth-leakage-circuit-breaker-dpn-n-vigi-1p-+-n-20a-30ma/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N19666/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy A9N19666 and how do I get a price?","answer":"The A9N19666 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."},{"question":"What is A9N19666's Type AC rating?","answer":"The A9N19666 is a Type AC residual-current device, meaning it detects sinusoidal AC earth-leakage currents only. It is the standard type for general-purpose circuits without non-sinusoidal or pulsating DC fault currents."},{"question":"What is the breaking capacity of A9N19666?","answer":"The A9N19666 has a 6000 A Icn breaking capacity at 230 V AC, conforming to EN 61009. This is sufficient for most residential and light commercial distribution boards where the prospective short-circuit current is below 6 kA."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N19666","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N19666 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}