{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N19669","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N19669","canonicalUrl":"https://aoctrl.com/schneider/A9N19669","factsUrl":"https://aoctrl.com/api/mcp/products/A9N19669","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 DPN N Vigi RCBO, 40 A, Type AC, 30 mA, Curve C, 6 kA, 1P+N, DIN rail.","salesMarkdown":"The Schneider Electric A9N19669 is an Acti9 DPN N Vigi RCBO — a combined overcurrent and earth-leakage circuit breaker in a single 1P+N module. It protects a single-phase outgoing circuit against overload, short-circuit (thermal-magnetic trip, Curve C: 5…10 x In magnetic limit), and residual earth faults. The 40 A rated current (at 30 °C) and 30 mA Type AC earth-leakage sensitivity cover standard residential and light commercial distribution boards where the load is resistive or slightly inductive — lighting, general-purpose sockets, small appliances. The 6 kA breaking capacity (Icn at 230 V AC, per EN 61009) is adequate for most domestic sub-distribution boards but check the prospective fault current at the installation point — if it exceeds 6 kA, step up to a higher-rated unit. Mounts on DIN rail (EN 60715) and occupies 4 x 9 mm pitches — a compact 36 mm width for a 1P+N RCBO. Neutral is on the left, phase on the right. Tunnel terminals accept up to 16 mm² rigid or 10 mm² flexible cable, which is generous for a 40 A outgoing circuit. The toggle gives local ON/OFF indication; the contact position indicator shows the state of the main contacts even with the toggle in the tripped position.","metaTitle":"Schneider Electric A9N19669 Acti9 DPN N Vigi RCBO, 40A Type","metaDescription":"Schneider Electric A9N19669 Acti9 DPN N Vigi RCBO, 40 A rated current, 30 mA Type AC earth leakage, 6 kA breaking capacity, Curve C. Current production. Sourced to order against RF","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Type":"Type AC","Range":"Acti9","Colour":"White","Standards":"EN/IEC 61009-1 EN/IEC 61009-2-1","Curve code":"C","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"DPN Vigi","Tropicalisation":"2 conforming to EN 61009","lifecycle_stage":"current","Limitation class":"3 conforming to EN 61009","Local signalling":"ON/OFF indication","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3 conforming to EN 61009","Breaking capacity":"6000 A Icn at 230 V AC conforming to EN 61009","Device short name":"DPN N Vigi","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Operating altitude":"2000 m","[In] rated current":"40 A at 30 °C","Overvoltage category":"III","Trip unit technology":"Thermal-magnetic","Electrical durability":"10000 cycles conforming to IEC 61009","Mechanical durability":"20000 cycles","Connections - terminals":"Tunnel type terminals1 cable(s) 10 mm² flexible Tunnel type terminals1 cable(s) 16 mm² rigid","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"30 mA","Number of protected poles":"1","Product or component type":"Earth leakage circuit breaker","Contact position indicator":"Yes","Circuit breaker application":"Distribution","[Ui] rated insulation voltage":"400 V AC conforming to EN 61009","[Ue] rated operational voltage":"230 V AC","Ambient air temperature for storage":"-40...60 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-5...60 °C","[Ics] rated service breaking capacity":"6000 A at 230 V AC 50/60 Hz conforming to EN 61009","[Uimp] rated impulse withstand voltage":"4 kV conforming to EN 61009"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a4db50587116d2cf7c498e12bbfbc74c.pdf","sourceUrl":"https://www.se.com/th/en/product/A9N19669/residual-current-breaker-with-overcurrent-protection-rcbo-acti9-dpn-n-vigi-1p+n-40a-30ma-ac-type-6000a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N19669/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of the A9N19669?","answer":"The breaking capacity is 6000 A Icn at 230 V AC, conforming to EN 61009. That is adequate for most residential and light commercial sub-distribution boards."},{"question":"What type of earth-leakage protection does the A9N19669 provide?","answer":"Type AC — it detects sinusoidal AC residual currents only. For circuits with pulsed DC or variable-speed drives, choose Type A or Type F instead."},{"question":"Where can I buy the A9N19669 and get current pricing?","answer":"The A9N19669 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What compliance standards does the A9N19669 meet?","answer":"It conforms to EN/IEC 61009-1 and EN/IEC 61009-2-1, with tropicalisation class 2 and limitation class 3 per EN 61009."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N19669","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N19669 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}