{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N19673","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N19673","canonicalUrl":"https://aoctrl.com/schneider/A9N19673","factsUrl":"https://aoctrl.com/api/mcp/products/A9N19673","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 DPN N Vigi, RCBO, 1P+N, 10 A, B-curve, 300 mA Type AC, 6 kA, DIN rail.","salesMarkdown":"The Schneider Electric A9N19673 is a DPN N Vigi RCBO from the Acti9 range — a combined overcurrent and earth-leakage circuit breaker in a single 1P+N module. It protects a single pole plus neutral, with the neutral switched and on the left side of the unit. The 10 A rated current (at 30 °C) and B-curve (magnetic trip 3–5 × In) suit it for general-purpose distribution circuits feeding resistive and light inductive loads like lighting or socket outlets. The 300 mA Type AC earth-leakage sensitivity catches sinusoidal AC fault currents; it is the standard choice for basic shock protection in residential and commercial final circuits where no DC-sensitive or pulsed-current detection is required. That is the standard domestic and light commercial fault level in most European installations; for industrial panels with higher prospective short-circuit currents you would step to a 10 kA or 15 kA device. The limitation class 3 (per EN 61009) means let-through energy is low enough to protect downstream wiring and loads without cascading — a useful detail for panel builders coordinating with upstream MCCBs. That is the standard 1P+N modular footprint, so it fits directly into any Acti9 or Multi9 distribution board without re-spacing. The toggle gives clear ON/OFF indication, and the contact position indicator confirms the state even when the toggle is hidden behind a sealed cover.","metaTitle":"Schneider Electric A9N19673 DPN N Vigi RCBO, 10 A, Type AC,","metaDescription":"Schneider Electric A9N19673 DPN N Vigi RCBO, 10 A rated, Type AC earth-leakage, 300 mA sensitivity, 6 kA breaking capacity. Active production, sourced to order. Request RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Type":"Type AC","Range":"Acti9","Colour":"White","Standards":"EN/IEC 61009-1 EN/IEC 61009-2-1","Curve code":"B","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"DPN Vigi","Tropicalisation":"2 conforming to EN 61009","lifecycle_stage":"current","Limitation class":"3 conforming to EN 61009","Local signalling":"ON/OFF indication","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3 conforming to EN 61009","Breaking capacity":"6000 A Icn at 230 V AC 50/60 Hz conforming to EN 61009","Device short name":"DPN N Vigi","Network frequency":"50/60 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Operating altitude":"2000 m","[In] rated current":"10 A at 30 °C","Overvoltage category":"III","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles conforming to IEC 61009","Mechanical durability":"20000 cycles","Connections - terminals":"Tunnel type terminals1 cable(s) 10 mm² flexible Tunnel type terminals1 cable(s) 16 mm² rigid","Magnetic tripping limit":"3...5 x In","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"300 mA","Number of protected poles":"1","Product or component type":"Earth leakage circuit breaker","Contact position indicator":"Yes","Circuit breaker application":"Distribution","[Ui] rated insulation voltage":"400 V AC conforming to EN 61009","[Ue] rated operational voltage":"230 V AC 50/60 Hz","Ambient air temperature for storage":"-40...60 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-5...60 °C","[Ics] rated service breaking capacity":"6000 A at 230 V AC 50/60 Hz conforming to EN 61009","[Uimp] rated impulse withstand voltage":"4 kV conforming to EN 61009"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/bb2082c83a231d98636fa6ed3930dd4e.pdf","sourceUrl":"https://www.se.com/vn/en/product/A9N19673/acti9-earth-leakage-circuit-breaker-dpn-n-vigi-1p-+-n-10a-300ma/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N19673/alternatives.json"},"ai":{"faq":[{"question":"What is A9N19673's listed type and range?","answer":"The A9N19673 is a Type AC earth-leakage circuit breaker from the Schneider Electric Acti9 range. The 'DPN N Vigi' designation indicates a 1P+N RCBO with integrated earth-leakage protection."},{"question":"Where can I buy A9N19673 and how is it quoted?","answer":"The A9N19673 is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm quote."},{"question":"What compliance documentation does Schneider provide for A9N19673?","answer":"The A9N19673 is certified to EN/IEC 61009-1 and EN/IEC 61009-2-1. It carries a pollution degree 3 rating and tropicalisation class 2 per EN 61009. Standard Schneider documentation includes the declaration of conformity and CE marking; specific RoHS/REACH declarations are available on request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N19673","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N19673 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}