{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N19675","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N19675","canonicalUrl":"https://aoctrl.com/schneider/A9N19675","factsUrl":"https://aoctrl.com/api/mcp/products/A9N19675","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 DPN Vigi RCBO, 1P+N, 16 A, B curve, 300 mA Type AC residual, 6 kA breaking capacity, thermal-magnetic trip, DIN rail mount.","salesMarkdown":"## What this RCBO does for a distribution board The A9N19675 is a single-module (4 x 9 mm pitches) DPN Vigi residual-current circuit breaker from the Acti9 range, combining overcurrent and earth-leakage protection in one 1P+N package. Its 16 A rated current at 30 °C and B curve (magnetic trip at 3 to 5 times In) suit it for general-purpose socket-outlet and lighting circuits where inrush is low and nuisance tripping on cable charging is a risk. Snaps onto DIN rail. Tunnel-type terminals accept one 10 mm² flexible or 16 mm² rigid conductor. Neutral is on the left (fixed position). The toggle provides ON/OFF indication. Certified to EN/IEC 61009-1 and EN/IEC 61009-2-1. Tropicalisation class 2 per EN 61009. Limitation class 3. Electrical and mechanical durability both rated at 20,000 cycles. Storage temperature range -40 to +60 °C.","metaTitle":"Schneider Electric A9N19675 DPN Vigi 16A B Curve 30mA RCBO,","metaDescription":"Schneider Electric A9N19675 DPN Vigi RCBO, 16A rated, B curve, 300mA residual sensitivity, 6kA breaking capacity at 230V. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Type":"Type AC","Range":"Acti9","Colour":"White","Standards":"EN/IEC 61009-1 EN/IEC 61009-2-1","Curve code":"B","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"DPN Vigi","Tropicalisation":"2 conforming to EN 61009","lifecycle_stage":"current","Limitation class":"3 conforming to EN 61009","Local signalling":"ON/OFF indication","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3 conforming to EN 61009","Breaking capacity":"6000 A Icn at 230 V AC 50/60 Hz conforming to EN 61009","Device short name":"DPN N Vigi","Network frequency":"50/60 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Operating altitude":"2000 m","[In] rated current":"16 A at 30 °C","Overvoltage category":"III","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles conforming to IEC 61009","Mechanical durability":"20000 cycles","Connections - terminals":"Tunnel type terminals1 cable(s) 10 mm² flexible Tunnel type terminals1 cable(s) 16 mm² rigid","Magnetic tripping limit":"3...5 x In","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"300 mA","Number of protected poles":"1","Product or component type":"Earth leakage circuit breaker","Contact position indicator":"Yes","Circuit breaker application":"Distribution","[Ui] rated insulation voltage":"400 V AC conforming to EN 61009","[Ue] rated operational voltage":"230 V AC 50/60 Hz","Ambient air temperature for storage":"-40...60 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-5...60 °C","[Ics] rated service breaking capacity":"6000 A at 230 V AC 50/60 Hz conforming to EN 61009","[Uimp] rated impulse withstand voltage":"4 kV conforming to EN 61009"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b47a812fd672093ce7e4087e84e3e002.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9N19675/acti9-earth-leakage-circuit-breaker-dpn-n-vigi-1p-+-n-16a-300ma/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N19675/alternatives.json"},"ai":{"faq":[{"question":"What is the Type AC residual rating on this RCBO?","answer":"Type AC means it detects sinusoidal alternating earth-leakage currents only. It will not trip on pulsed DC or smooth DC waveforms, so for loads with power electronics (VFDs, LED drivers, UPS) a Type A or Type B device is required."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N19675","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N19675 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}