{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N19681","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N19681","canonicalUrl":"https://aoctrl.com/schneider/A9N19681","factsUrl":"https://aoctrl.com/api/mcp/products/A9N19681","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 DPN N Vigi RCBO, 1P+N, 6 A, C-curve, 300 mA Type AC, 6 kA, DIN rail.","salesMarkdown":"The Schneider Electric A9N19681 is a DPN N Vigi residual-current circuit breaker (RCBO) from the Acti9 range, combining overcurrent protection and earth-leakage detection in a single 1P+N module. The 6 A rated current with a C-curve magnetic trip (5–10 × In) means it is sized for lighting circuits, small motorised loads, or general-purpose socket outlets where inrush currents up to 10× the rating are expected — a C-curve holds through the start-up surge of a small fan or pump without nuisance tripping, provided the prospective short-circuit current at the point of installation does not exceed 6 kA. The 300 mA Type AC earth-leakage protection is voltage-independent, meaning the residual current detection operates without an auxiliary supply — it will still trip on a line-to-earth fault even if the neutral is lost upstream. Type AC detection responds to sinusoidal alternating residual currents; for a distribution board feeding general-purpose socket outlets and lighting in a commercial or light-industrial outgoer position, this is the standard choice. The instantaneous time delay (no intentional delay) ensures the RCBO clears earth faults within the IEC 61009 waveform cycle, provided the fault current exceeds 300 mA. In a typical UK or EU distribution board with a 100 A upstream fuse or a 63 A MCB, the available fault current at the outgoer is usually well below 6 kA — but if the RCBO sits close to a large transformer (say, within 10 m of a 630 kVA unit), coordination with the upstream device must be verified to keep the let-through energy within the RCBO's rating. ## Integration notes The toggle switch provides ON/OFF indication and manual isolation. Operating altitude is limited to 2000 m; above that, dielectric withstand and breaking capacity derate.","metaTitle":"Schneider Electric A9N19681 DPN Vigi 6A C-Curve 30mA RCBO, A","metaDescription":"Schneider Electric A9N19681 DPN N Vigi RCBO, 6A C-curve, 300mA Type AC earth leakage, 6kA breaking capacity. Active production. Sourced to order, RFQ for current pricing.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Type":"Type AC","Range":"Acti9","Colour":"White","Standards":"EN/IEC 61009-1 EN/IEC 61009-2-1","Curve code":"C","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"DPN Vigi","Tropicalisation":"2 conforming to EN 61009","lifecycle_stage":"current","Limitation class":"3 conforming to EN 61009","Local signalling":"ON/OFF indication","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3 conforming to EN 61009","Breaking capacity":"6000 A Icn at 230 V AC conforming to EN 61009","Device short name":"DPN N Vigi","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Operating altitude":"2000 m","[In] rated current":"6 A at 30 °C","Overvoltage category":"III","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles conforming to IEC 61009","Mechanical durability":"20000 cycles","Connections - terminals":"Tunnel type terminals1 cable(s) 10 mm² flexible Tunnel type terminals1 cable(s) 16 mm² rigid","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"300 mA","Number of protected poles":"1","Product or component type":"Earth leakage circuit breaker","Contact position indicator":"Yes","Circuit breaker application":"Distribution","[Ui] rated insulation voltage":"400 V AC conforming to EN 61009","[Ue] rated operational voltage":"230 V AC","Ambient air temperature for storage":"-40...60 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-5...60 °C","[Ics] rated service breaking capacity":"6000 A at 230 V AC 50/60 Hz conforming to EN 61009","[Uimp] rated impulse withstand voltage":"4 kV conforming to EN 61009"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/3bad113916373dc887db033115e302ec.pdf","sourceUrl":"https://www.se.com/vn/en/product/A9N19681/residual-current-breaker-with-overcurrent-protection-rcbo-acti9-dpn-n-vigi-1p+n-6a-300ma-ac-type-6000a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N19681/alternatives.json"},"ai":{"faq":[{"question":"What is the A9N19681's earth-leakage sensitivity and type?","answer":"The A9N19681 has a 300 mA Type AC earth-leakage sensitivity, integrated into the RCBO. Type AC detects sinusoidal alternating residual currents. The protection is voltage-independent, meaning it will trip on an earth fault even if the neutral supply is lost upstream."},{"question":"What compliance standards does the A9N19681 meet?","answer":"The A9N19681 complies with EN/IEC 61009-1 and EN/IEC 61009-2-1, the harmonised standards for residual-current operated circuit breakers with integral overcurrent protection (RCBOs). It carries tropicalisation class 2 and limitation class 3 per EN 61009."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N19681","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N19681 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}