{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N19683","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N19683","canonicalUrl":"https://aoctrl.com/schneider/A9N19683","factsUrl":"https://aoctrl.com/api/mcp/products/A9N19683","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 DPN Vigi RCBO, Type AC, 1P+N, 10 A, C-curve, 300 mA earth leakage, 6 kA breaking capacity, DIN rail mount, white.","salesMarkdown":"The Schneider Electric A9N19683 is a DPN Vigi residual current circuit breaker with overcurrent protection (RCBO) from the Acti9 range, combining a 1P+N thermal-magnetic MCB and a voltage-independent earth leakage module in a single 4-module (9 mm pitch) DIN-rail unit. Rated 10 A at 30 °C with a C-curve magnetic trip (5...10 x In), it breaks 6000 A Icn at 230 V AC per EN 61009 — enough for final subcircuits in residential or light commercial distribution boards where fault current stays under 6 kA. The integrated earth leakage protection is Type AC, 300 mA sensitivity, instantaneous trip — suited for general-purpose socket circuits and lighting where sinusoidal AC residual currents are the expected fault type. ## Integration notes Mounts on standard DIN rail; occupies 4 modules (36 mm) of panel width. Neutral is on the left (fixed position). Rated insulation voltage 400 V AC, operational voltage 230 V AC. Ambient storage range -40 to 60 °C; operating altitude up to 2000 m; relative humidity 95 % at 55 °C.","metaTitle":"Schneider Electric A9N19683 DPN Vigi RCBO, 10A C-Curve 30mA","metaDescription":"Schneider Electric A9N19683 DPN Vigi RCBO, 10A rated, C-curve, 300mA AC type earth leakage, 6kA breaking capacity. Active production. Available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Type":"Type AC","Range":"Acti9","Colour":"White","Standards":"EN/IEC 61009-2-1 EN/IEC 61009-1","Curve code":"C","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"DPN Vigi","Tropicalisation":"2 conforming to EN 61009","lifecycle_stage":"current","Limitation class":"3 conforming to EN 61009","Local signalling":"ON/OFF indication","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3 conforming to EN 61009","Breaking capacity":"6000 A Icn at 230 V AC conforming to EN 61009","Device short name":"DPN N Vigi","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Operating altitude":"2000 m","[In] rated current":"10 A at 30 °C","Overvoltage category":"III","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles conforming to IEC 61009","Mechanical durability":"20000 cycles","Connections - terminals":"Tunnel type terminals1 cable(s) 10 mm² flexible Tunnel type terminals1 cable(s) 16 mm² rigid","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"300 mA","Number of protected poles":"1","Product or component type":"Earth leakage circuit breaker","Contact position indicator":"Yes","Circuit breaker application":"Distribution","[Ui] rated insulation voltage":"400 V AC conforming to EN 61009","[Ue] rated operational voltage":"230 V AC","Ambient air temperature for storage":"-40...60 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-5...60 °C","[Ics] rated service breaking capacity":"6000 A at 230 V AC 50/60 Hz conforming to EN 61009","[Uimp] rated impulse withstand voltage":"4 kV conforming to EN 61009"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f1f8e7e3c1fb0d38daa861b94bf5f319.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9N19683/residual-current-breaker-with-overcurrent-protection-rcbo-acti9-dpn-n-vigi-1p+n-10a-300ma-ac-type-6000a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N19683/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for A9N19683?","answer":"Submit an RFQ through the storefront; pricing and stock are confirmed at quote time through independent distribution channels."},{"question":"What is A9N19683's listed type (Type AC) on this component line?","answer":"The A9N19683 is a Type AC residual current device, meaning it detects sinusoidal AC earth leakage currents only."},{"question":"What is A9N19683's listed range (Acti9) on this component line?","answer":"The A9N19683 belongs to the Schneider Electric Acti9 range, a modular DIN-rail system for final distribution."},{"question":"What compliance documentation does this brand provide for A9N19683?","answer":"The A9N19683 complies with EN/IEC 61009-1 and EN/IEC 61009-2-1, and carries pollution degree 3 and overvoltage category III ratings. RoHS, REACH, and CE documentation is available from the manufacturer."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N19683","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N19683 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}