{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N19685","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N19685","canonicalUrl":"https://aoctrl.com/schneider/A9N19685","factsUrl":"https://aoctrl.com/api/mcp/products/A9N19685","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 DPN N Vigi RCBO, 16 A, Type AC, 300 mA sensitivity, 6 kA breaking capacity, 1P+N, white.","salesMarkdown":"It protects a single-phase outgoing circuit against overload, short-circuit, and earth faults, all in one DIN-rail footprint. The 5...10 x In magnetic trip range means it clears short-circuits quickly without nuisance tripping on moderate inrush. The Type AC earth-leakage detection responds to sinusoidal AC residual currents at 50/60 Hz. At 300 mA sensitivity, this is sized for whole-circuit or sub-distribution protection where personnel protection is not the primary goal — think feeder protection or equipment with known leakage, not socket-outlet final circuits where 30 mA is standard for shock protection. Breaking capacity is 6000 A Icn at 230 V AC, conforming to EN 61009. That covers typical domestic and light commercial panel fault levels; for installations with higher prospective short-circuit current, a current-limiting upstream MCB or fuse is needed. ## DIN-rail and panel integration The 36 mm width occupies 4 module pitches at 9 mm each. Depth is 77.5 mm with an embedding depth of 44 mm — the part that sits behind the panel cutout. Plan for clearance in the gland plate or enclosure depth. Designed to EN/IEC 61009-1 and EN/IEC 61009-2-1, the standards for RCBOs. Limitation class 3 and pollution degree 3 are per the same standard. Overvoltage category IV suits it for main distribution panels. Electrical and mechanical durability are both 20000 cycles.","metaTitle":"Schneider Electric A9N19685 DPN N Vigi RCBO, 16A Type AC 30m","metaDescription":"Schneider Electric A9N19685 DPN N Vigi RCBO, 16A rated, Type AC earth-leakage, 300mA sensitivity, 6kA breaking capacity, 1P+N, current production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Type":"Type AC","Depth":"77.5 mm","Range":"Acti9","Width":"36 mm","title":"A9N19685","Colour":"White","Height":"81 mm","Standards":"EN/IEC 61009-1 EN/IEC 61009-2-1","Curve code":"C","description":"residual current breaker with overcurrent protection (RCBO), Acti9 DPN N Vigi, 1P+N, 16A, 300mA, AC type, 6000A","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"DPN Vigi","Embedding depth":"44 mm","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN 61009","Local signalling":"ON/OFF indication","Mounting support":"35 mm DIN rail","Neutral position":"Left","Pollution degree":"3 conforming to EN 61009","Breaking capacity":"6000 A Icn at 230 V AC conforming to EN 61009","Device short name":"DPN N Vigi","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Operating altitude":"2000 m","[In] rated current":"16 A at 30 °C","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A","Electrical durability":"20000 cycles conforming to IEC 61009","Mechanical durability":"20000 cycles","Wire stripping length":"15 mm for top or bottom connection","Connections - terminals":"Tunnel type terminals (top or bottom) 1 cable(s) 1...10 mm² flexible with ferrule Tunnel type terminals (top or bottom) 1 cable(s) 1...16 mm² rigid","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"300 mA","Number of protected poles":"1","Product or component type":"Earth leakage circuit breaker","Contact position indicator":"Yes","Circuit breaker application":"Distribution","[Ui] rated insulation voltage":"400 V AC conforming to EN 61009","[Ue] rated operational voltage":"230 V AC","Ambient air temperature for storage":"-30...70 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-5...60 °C","[Ics] rated service breaking capacity":"6000 A at 230 V AC 50/60 Hz conforming to EN 61009","[Uimp] rated impulse withstand voltage":"4 kV conforming to EN 61009"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/52fb48a97c4dac0501dae36eddbf1e68.pdf","sourceUrl":"https://www.se.com/vn/en/product/A9N19685/residual-current-breaker-with-overcurrent-protection-rcbo-acti9-dpn-n-vigi-1p+n-16a-300ma-ac-type-6000a/"},"ai":{"faq":[{"question":"What is the breaking capacity of A9N19685?","answer":"6000 A Icn at 230 V AC conforming to EN 61009. This is the rated short-circuit breaking capacity for this RCBO."},{"question":"What is the earth-leakage sensitivity of A9N19685?","answer":"300 mA, Type AC detection for sinusoidal AC residual currents. This is a higher threshold suited for feeder or sub-distribution protection rather than final-circuit shock protection."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N19685","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N19685 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}