{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N19686","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N19686","canonicalUrl":"https://aoctrl.com/schneider/A9N19686","factsUrl":"https://aoctrl.com/api/mcp/products/A9N19686","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 DPN N Vigi RCBO, Type AC, C-curve, 20 A, 300 mA, 6 kA, 1P+N, DIN rail.","salesMarkdown":"The 300 mA sensitivity (IΔn) is the residual-current threshold — it catches leakage to earth but is less sensitive than a 30 mA unit, so it suits submain or outgoer circuits where some natural leakage is expected and you want to avoid spurious trips. The Type AC residual-current detection means it trips on sinusoidal AC leakage only — not on pulsed DC or smooth DC. That is fine for circuits feeding resistive loads, heaters, and standard AC motors, but if the downstream equipment includes variable-speed drives, UPS systems, or LED drivers that can generate DC fault currents, you need a Type A or Type B RCBO instead. ## Mounting and wiring in the enclosure The toggle gives clear ON/OFF indication, and the contact-position indicator confirms the state even with the cover closed. Operating altitude is 2000 m; above that, dielectric strength and cooling derate.","metaTitle":"Schneider Electric A9N19686 DPN N Vigi RCBO, 20 A, 30 mA, Ty","metaDescription":"Schneider Electric A9N19686 Acti9 DPN N Vigi RCBO. 20 A rated, 300 mA sensitivity, 6 kA breaking capacity, Type AC, C-curve. DIN rail mount. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Type":"Type AC","Range":"Acti9","Colour":"White","Standards":"EN/IEC 61009-2-1 EN/IEC 61009-1","Curve code":"C","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"DPN Vigi","Tropicalisation":"2 conforming to EN 61009","lifecycle_stage":"current","Limitation class":"3 conforming to EN 61009","Local signalling":"ON/OFF indication","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3 conforming to EN 61009","Breaking capacity":"6000 A Icn at 230 V AC conforming to EN 61009","Device short name":"DPN N Vigi","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Operating altitude":"2000 m","[In] rated current":"20 A at 30 °C","Overvoltage category":"III","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles conforming to IEC 61009","Mechanical durability":"20000 cycles","Connections - terminals":"Tunnel type terminals1 cable(s) 10 mm² flexible Tunnel type terminals1 cable(s) 16 mm² rigid","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"300 mA","Number of protected poles":"1","Product or component type":"Earth leakage circuit breaker","Contact position indicator":"Yes","Circuit breaker application":"Distribution","[Ui] rated insulation voltage":"400 V AC conforming to EN 61009","[Ue] rated operational voltage":"230 V AC","Ambient air temperature for storage":"-40...60 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-5...60 °C","[Ics] rated service breaking capacity":"6000 A at 230 V AC 50/60 Hz conforming to EN 61009","[Uimp] rated impulse withstand voltage":"4 kV conforming to EN 61009"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/27387bf3bd9595de109000530c59b8b4.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9N19686/residual-current-breaker-with-overcurrent-protection-rcbo-acti9-dpn-n-vigi-1p+n-20a-300ma-ac-type-6000a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N19686/alternatives.json"},"ai":{"faq":[{"question":"What is the A9N19686's breaking capacity?","answer":"6000 A Icn at 230 V AC, conforming to EN 61009."},{"question":"What is the earth-leakage sensitivity of the A9N19686?","answer":"300 mA, Type AC, instantaneous trip — no intentional time delay."},{"question":"Where can I buy the A9N19686 and how is it quoted?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock count or price is published here."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N19686","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N19686 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}