{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N19688","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N19688","canonicalUrl":"https://aoctrl.com/schneider/A9N19688","factsUrl":"https://aoctrl.com/api/mcp/products/A9N19688","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 DPN N Vigi RCBO, 1P+N, 32 A, C-curve, 300 mA Type AC residual current, 6 kA breaking capacity, DIN rail.","salesMarkdown":"The 32 A rated current and C-curve magnetic trip (5–10× In) mean it handles general-purpose loads like lighting, socket circuits, and small distribution boards where inrush from motor-start or capacitive loads is moderate. The 300 mA sensitivity and Type AC detection mean it trips on sinusoidal AC residual currents only; it is the baseline choice for circuits where no pulsed DC or mixed-frequency leakage is expected (resistive heaters, general sockets, basic lighting). The voltage-independent residual current trip technology means the earth-leakage function operates even if the mains voltage is lost — a safety advantage in fault conditions where the line voltage collapses. The toggle gives clear ON/OFF indication. Standards compliance covers EN/IEC 61009-1 and 61009-2-1, which is the harmonized European standard for RCBOs. Tropicalisation class 2 per EN 61009 means it withstands 95 % relative humidity at 55 °C and operates up to 2000 m altitude. The 10,000-cycle electrical durability and 20,000-cycle mechanical durability are standard for this class — the device is built for years of daily switching in a distribution board.","metaTitle":"Schneider Electric A9N19688 DPN N Vigi RCBO, 32A C-Curve 30m","metaDescription":"Schneider Electric A9N19688 Acti9 DPN N Vigi RCBO. 32 A rated, C-curve, 300 mA Type AC earth leakage, 6 kA breaking capacity. DIN rail mount. Current production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Type":"Type AC","Range":"Acti9","title":"A9N19688","Colour":"White","Standards":"EN/IEC 61009-2-1 EN/IEC 61009-1","Curve code":"C","description":"residual current breaker with overcurrent protection (RCBO), Acti9 DPN N Vigi, 1P+N, 32A, 300mA, AC type, 6000A","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"DPN Vigi","Tropicalisation":"2 conforming to EN 61009","lifecycle_stage":"current","Limitation class":"3 conforming to EN 61009","Local signalling":"ON/OFF indication","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3 conforming to EN 61009","Breaking capacity":"6000 A Icn at 230 V AC conforming to EN 61009","Device short name":"DPN N Vigi","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Operating altitude":"2000 m","[In] rated current":"32 A at 30 °C","Overvoltage category":"III","Trip unit technology":"Thermal-magnetic","Electrical durability":"10000 cycles conforming to IEC 61009","Mechanical durability":"20000 cycles","Connections - terminals":"Tunnel type terminals1 cable(s) 10 mm² flexible Tunnel type terminals1 cable(s) 16 mm² rigid","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Integrated","Device location in system":"Outgoer","Earth-leakage sensitivity":"300 mA","Number of protected poles":"1","Product or component type":"Earth leakage circuit breaker","Contact position indicator":"Yes","Circuit breaker application":"Distribution","[Ui] rated insulation voltage":"400 V AC conforming to EN 61009","[Ue] rated operational voltage":"230 V AC","Ambient air temperature for storage":"-40...60 °C","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-5...60 °C","[Ics] rated service breaking capacity":"6000 A at 230 V AC 50/60 Hz conforming to EN 61009","[Uimp] rated impulse withstand voltage":"4 kV conforming to EN 61009"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/da7660ad3cc0577c4941452eb470d77f.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9N19688/residual-current-breaker-with-overcurrent-protection-rcbo-acti9-dpn-n-vigi-1p+n-32a-300ma-ac-type-6000a/"},"ai":{"faq":[{"question":"What is the A9N19688's Type AC rating?","answer":"The Type AC rating means the residual current detection responds to sinusoidal AC earth-leakage currents only. It is the standard type for circuits without electronic loads that generate pulsed DC or high-frequency leakage."},{"question":"What compliance documentation does Schneider provide for the A9N19688?","answer":"The device is certified to EN/IEC 61009-1 and EN/IEC 61009-2-1, which covers the RCBO standard. Tropicalisation class 2 per EN 61009 is also documented. For specific RoHS, REACH, or UL declarations, request the manufacturer's compliance pack with your RFQ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N19688","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N19688 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}