{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N19815","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N19815","canonicalUrl":"https://aoctrl.com/schneider/A9N19815","factsUrl":"https://aoctrl.com/api/mcp/products/A9N19815","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 C120H, 4P, 80 A, D curve, 10 kA, miniature circuit breaker (MCB).","salesMarkdown":"The Schneider Electric A9N19815 is an Acti9 C120H miniature circuit breaker — 4 poles, 80 A rated current at 30 °C, D curve, with 10 kA breaking capacity per IEC 60947-2 and IEC 60898-1. Thermal-magnetic trip unit, clip-on mount to DIN rail, tunnel terminals accepting up to 50 mm² rigid. Suited for distribution in commercial and industrial panels where high inrush loads (transformers, motors) demand the D-curve magnetic trip at 10–14 × In. Active in production.","metaTitle":"A9N19815 Acti9 C120H MCB, 4P, 80A, D Curve, 10kA","metaDescription":"Schneider Electric A9N19815 Acti9 C120H miniature circuit breaker, 4-pole, 80A rated current, D curve, 10 kA breaking capacity to IEC 60947-2. Active production. Available to order","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"73 mm","Range":"Acti9","Height":"81 mm","Standards":"GB 10963.1 EN/IEC 60898-1 GB/T 14048.2 EN/IEC 60947-2","Curve code":"D","9 Mm Pitches":"12.0","Control type":"Toggle","Network type":"AC","Product name":"C120","Mounting mode":"Clip-on","lifecycle_stage":"current","Local signalling":"ON/OFF indication","Mounting support":"DIN rail","Range of product":"Acti9","Breaking capacity":"10 kA Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 10 kA Icn at 400 V AC 50/60 Hz conforming to GB/T 10963.1 10 kA Icu at 400 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 400 V AC 50/60 Hz conforming to GB/T 14048.2","Device short name":"C120H","Network frequency":"50/60 Hz","Poles description":"4P","Tightening torque":"Power circuit: 3.5 N.m","Device application":"Distribution","[In] rated current":"80 A at 30 °C","Trip unit technology":"Thermal-magnetic","Electrical durability":"5000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"Power circuit: 14 mm","Connections - terminals":"Tunnel type terminals top or bottom 1...50 mm² rigid without cable end Tunnel type terminals top or bottom 1.5...35 mm² flexible with or without cable end","Magnetic tripping limit":"10...14 x In conforming to GB/T 10963.1 12 x In +/- 20 % conforming to GB/T 14048.2","Number of protected poles":"4","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz","[Ue] rated operational voltage":"400 V","Ambient air temperature for storage":"-40...80 °C","Ambient air temperature for operation":"-30...70 °C","[Uimp] rated impulse withstand voltage":"6 kV"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/be/en/product/A9N19815/miniature-circuit-breaker-mcb-acti9-c120h-4p-80a-d-curve-10ka-iec-en-609472/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N19815/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings of A9N19815?","answer":"Rated current 80 A at 30 °C, D curve, 4 poles, breaking capacity 10 kA Icn/Icu at 400 V AC, thermal-magnetic trip, clip-on DIN rail mount."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N19815","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N19815 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}