{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N19816","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N19816","canonicalUrl":"https://aoctrl.com/schneider/A9N19816","factsUrl":"https://aoctrl.com/api/mcp/products/A9N19816","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 C120H, miniature circuit breaker, 100 A, 1 pole, C curve, 10 kA breaking capacity, A9N19816.","salesMarkdown":"The Schneider Electric A9N19816 is a miniature circuit breaker from the Acti9 C120H range, rated 100 A at 30 °C, single-pole, with a C curve and a breaking capacity of 10 kA Icn/Icu at 230 V AC. The breaker is certified to GB 10963.1, EN/IEC 60898-1, GB/T 14048.2, and EN/IEC 60947-2. The dual standard means it meets both the household (60898-1) and industrial (60947-2) requirements — useful when the same panel must satisfy both a local code and an end-client's specification. The 6 kV impulse withstand voltage (Uimp) and 500 V rated insulation voltage (Ui) confirm it handles typical transient overvoltages in a 230/400 V network. ## Panel integration Tunnel terminals accept up to 50 mm² rigid or 35 mm² flexible cable. The toggle provides local ON/OFF indication and a contact-position indicator confirms the state for isolation — the breaker is marked suitable for isolation per the standards.","metaTitle":"Schneider Electric A9N19816 Acti9 C120H MCB, 100A 1P C Curve","metaDescription":"Schneider Electric A9N19816 Acti9 C120H miniature circuit breaker, 100A, 1P, C curve, 10 kA breaking capacity. Obsolete — sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"73 mm","Range":"Acti9","Height":"81 mm","Standards":"GB 10963.1 EN/IEC 60898-1 GB/T 14048.2 EN/IEC 60947-2","Curve code":"C","9 Mm Pitches":"3","Control type":"Toggle","Network type":"AC DC","Product name":"C120","Mounting mode":"Clip-on","lifecycle_stage":"current","Local signalling":"ON/OFF indication","Mounting support":"DIN rail","Range of product":"Acti9","Breaking capacity":"10 kA Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1 10 kA Icn at 230 V AC 50/60 Hz conforming to GB/T 10963.1 10 kA Icu at 230 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 230 V AC 50/60 Hz conforming to GB/T 14048.2","Device short name":"C120H","Network frequency":"50/60 Hz","Poles description":"1P","Tightening torque":"Power circuit: 3.5 N.m","Device application":"Distribution","[In] rated current":"100 A at 30 °C","Trip unit technology":"Thermal-magnetic","Electrical durability":"5000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"Power circuit: 14 mm","Connections - terminals":"Tunnel type terminals top or bottom 1...50 mm² rigid without cable end Tunnel type terminals top or bottom 1.5...35 mm² flexible with or without cable end","Magnetic tripping limit":"5...10 x In conforming to GB/T 10963.1 8 x In +/- 20 % conforming to GB/T 14048.2","Number of protected poles":"1","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz","[Ue] rated operational voltage":"230 V","Ambient air temperature for storage":"-40...80 °C","Ambient air temperature for operation":"-30...70 °C","[Uimp] rated impulse withstand voltage":"6 kV"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d213bcdfbdbb19001e369610009dc0f3.pdf","sourceUrl":"https://www.se.com/be/en/product/A9N19816/miniature-circuit-breaker-acti9-c120h-100a1p-c-curve10ka/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N19816/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy A9N19816?","answer":"The A9N19816 is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is the breaking capacity of A9N19816?","answer":"The A9N19816 has a breaking capacity of 10 kA Icn/Icu at 230 V AC, 50/60 Hz, conforming to EN/IEC 60898-1 and EN/IEC 60947-2."},{"question":"What standards does A9N19816 comply with?","answer":"It complies with GB 10963.1, EN/IEC 60898-1, GB/T 14048.2, and EN/IEC 60947-2."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N19816","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N19816 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}