{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N19887","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N19887","canonicalUrl":"https://aoctrl.com/schneider/A9N19887","factsUrl":"https://aoctrl.com/api/mcp/products/A9N19887","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 DCP Vigi RCBO, A9N19887, 32 A, 30 mA, C-curve, 2P, 10 kA breaking capacity, DIN rail mount.","salesMarkdown":"The Schneider Electric A9N19887 is an Acti9 DCP Vigi RCBO — a residual current breaker with overcurrent protection, combining a 32 A thermal-magnetic MCB and a 30 mA earth-leakage module in a single 2-pole unit. Integrated 30 mA earth-leakage protection means this single device covers both overcurrent and residual current faults — saves a DIN space vs a separate RCCB + MCB pair, and the trip unit is thermal-magnetic, so no electronics to fail in the overcurrent path. The 30 mA sensitivity is the standard for personal protection against indirect contact in wet or general-purpose circuits. Tunnel-type terminals top and bottom accept 1...35 mm² rigid or 1...25 mm² flexible — strip 12 mm, torque to 2 N.m. IP20 on the body, IP40 inside a modular enclosure. The white housing and toggle control with ON/OFF/fault-trip local signalling make panel identification straightforward. Rated for isolation (suitability for isolation: yes) with a visible contact position indicator, but not padlockable — so if lockout/tagout is required at the device, plan for a separate locking mechanism upstream. Electrical durability 10,000 cycles, mechanical 20,000 cycles — solid for a distribution-board RCBO. ## Standards & approvals Tropicalisation class 2, 95 % RH at 55 °C — handles humid environments without derating.","metaTitle":"Schneider Electric A9N19887 Acti9 DCP Vigi RCBO, 32 A, 30 mA","metaDescription":"Schneider Electric A9N19887 Acti9 DCP Vigi RCBO, 32 A rated, 30 mA earth leakage, C-curve, 10 kA breaking capacity, 2P, DIN rail mount. Current lifecycle stage. Sourced to order ag","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"76 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"85 mm","Standards":"EN/IEC 61009-2-1","Curve code":"C","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 DCP Vigi","Mounting mode":"Clip-on","Tropicalisation":"2","lifecycle_stage":"current","Limitation class":"2","Local signalling":"ON, OFF, fault trip","Mounting support":"DIN rail","Breaking capacity":"10000 A Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1 10 kA Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2","Device short name":"DCP H Vigi","Network frequency":"50 Hz","Poles description":"2P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"32 A","Overvoltage category":"III","Trip unit technology":"Thermal-magnetic","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"12 mm for top or bottom connection","Connections - terminals":"Tunnel type terminal top or bottom 1...35 mm² rigid Tunnel type terminal top or bottom 1...25 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Integrated","Earth-leakage sensitivity":"30 mA","Number of protected poles":"2","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes","Contact position indicator":"Yes","Locking options description":"Non padlockable","Electromagnetic compatibility":"8/20 µs impulse withstand, 3000 A conforming to EN/IEC 61009-2-1","[Ui] rated insulation voltage":"500 V AC 50 Hz","Earth-leakage protection class":"Type A-SI (Super Immunised)","[Ue] rated operational voltage":"220...240 V AC 50 Hz","Rated breaking and making capacity":"Idm 4500 A at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...40 °C","[Ics] rated service breaking capacity":"7500 A 75 % x Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1 7.5 kA 75 % x Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2","[Uimp] rated impulse withstand voltage":"4 kV"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c3093ed592259785a5eade9981e02f9d.pdf","sourceUrl":"https://www.se.com/be/en/product/A9N19887/acti9-dcp-h-vigi-rcbo-2p-32a-c-curve-10000a-10ka-30ma-type-asi/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N19887/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of A9N19887?","answer":"10 kA Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1, and 10 kA Icu at the same voltage conforming to EN/IEC 60947-2."},{"question":"What is the earth-leakage sensitivity of A9N19887?","answer":"30 mA, integrated into the RCBO — no separate RCCB needed."},{"question":"What is the closest alternative to A9N19887 in the Acti9 range?","answer":"Within the Acti9 DCP Vigi family, the closest sibling would share the same 2P, 30 mA, C-curve platform but differ in rated current — the A9N19887 is the 32 A variant. No pin-compatible drop-in exists with different ratings; the physical footprint (4 modules) is consistent across the range."},{"question":"Where can I buy A9N19887?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N19887","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N19887 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}