{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N19892","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N19892","canonicalUrl":"https://aoctrl.com/schneider/A9N19892","factsUrl":"https://aoctrl.com/api/mcp/products/A9N19892","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 DCP Vigi, RCBO, 2P, 10 A, B curve, 30 mA earth leakage, 10 kA breaking capacity, DIN rail mount, A9N19892.","salesMarkdown":"The Schneider Electric A9N19892 is an Acti9 DCP Vigi residual current breaker with overcurrent protection (RCBO) — a 2-pole, 10 A unit with integrated 30 mA earth-leakage protection and a B-curve magnetic trip (3...5 x In). The 10 kA breaking capacity (Icn/Icu at 220...240 V AC, 50 Hz) is rated per EN/IEC 61009-2-1 and EN/IEC 60947-2, which means it can interrupt fault currents up to that level without welding contacts or cascading upstream — sized for residential and light commercial distribution boards where the prospective short-circuit current stays under 10 kA. The 10 A rated current (In) is the continuous load the RCBO can carry without tripping thermally — sized for a lighting circuit, a general-purpose socket ring, or a small appliance group. The 30 mA earth-leakage sensitivity provides personal protection against direct contact — it will disconnect within 300 ms at 150 mA leakage, per the EN/IEC 61009-2-1 standard. The thermal-magnetic trip technology is the workhorse: a bimetal strip handles overloads (time-delayed), and a solenoid handles short-circuits (instantaneous). The tunnel-type terminals accept 1...35 mm² rigid or 1...25 mm² flexible cable; tighten to 2 N·m, strip 12 mm. The toggle provides ON, OFF, and fault-trip local signalling, so a technician can see at a glance whether the device has tripped on leakage or overcurrent.","metaTitle":"Schneider Electric A9N19892 Acti9 DCP Vigi RCBO, 10 A, 30 mA","metaDescription":"Schneider Electric A9N19892 Acti9 DCP Vigi RCBO, 10 A rated, 30 mA earth leakage, B curve, 10 kA breaking capacity. Active production, sourced to order. Quoted on request.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Residual Current Breakers (RCCB/RCBO)"],"specifications":{"Depth":"76 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"85 mm","Standards":"EN/IEC 61009-2-1","Curve code":"B","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 DCP Vigi","Mounting mode":"Clip-on","Tropicalisation":"2","lifecycle_stage":"current","Limitation class":"2","Local signalling":"ON, OFF, fault trip","Mounting support":"DIN rail","Breaking capacity":"10000 A Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1 10 kA Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2","Device short name":"DCP H Vigi","Network frequency":"50 Hz","Poles description":"2P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"10 A","Overvoltage category":"III","Trip unit technology":"Thermal-magnetic","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"12 mm for top or bottom connection","Connections - terminals":"Tunnel type terminal top or bottom 1...35 mm² rigid Tunnel type terminal top or bottom 1...25 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529","Magnetic tripping limit":"3...5 x In","Earth-leakage protection":"Integrated","Earth-leakage sensitivity":"30 mA","Number of protected poles":"2","Product or component type":"Residual current breaker with overcurrent protection (RCBO)","Suitability for isolation":"Yes","Contact position indicator":"Yes","Locking options description":"Non padlockable","Electromagnetic compatibility":"8/20 µs impulse withstand, 3000 A conforming to EN/IEC 61009-2-1","[Ui] rated insulation voltage":"500 V AC 50 Hz","Earth-leakage protection class":"Type A-SI (Super Immunised)","[Ue] rated operational voltage":"220...240 V AC 50 Hz","Rated breaking and making capacity":"Idm 4500 A at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1","Earth-leakage protection time delay":"Instantaneous","Residual current tripping technology":"Voltage independent","Ambient air temperature for operation":"-25...40 °C","[Ics] rated service breaking capacity":"7500 A 75 % x Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1 7.5 kA 75 % x Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2","[Uimp] rated impulse withstand voltage":"4 kV"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/965d4af71f24ee19a0c3278638183f27.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9N19892/acti9-dcp-h-vigi-rcbo-2p-10a-b-curve-10000a-10ka-30ma-type-asi/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N19892/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of A9N19892?","answer":"The A9N19892 has a breaking capacity of 10,000 A Icn at 220...240 V AC, 50 Hz, conforming to EN/IEC 61009-2-1, and 10 kA Icu at the same voltage per EN/IEC 60947-2."},{"question":"What is the earth-leakage sensitivity of this RCBO?","answer":"The integrated earth-leakage protection is set at 30 mA sensitivity, providing personal protection against direct contact."},{"question":"Where can I buy A9N19892?","answer":"The A9N19892 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N19892","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N19892 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}