{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N1P02DIN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N1P02DIN","canonicalUrl":"https://aoctrl.com/schneider/A9N1P02DIN","factsUrl":"https://aoctrl.com/api/mcp/products/A9N1P02DIN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 xC60 miniature circuit-breaker, A9N1P02DIN, 1P, 2 A rated, D curve, 10 kA breaking capacity at 240 V AC, clip-on 35 mm DIN rail.","salesMarkdown":"The Schneider Electric A9N1P02DIN is an Acti9 xC60 miniature circuit-breaker rated 2 A with a D tripping curve, single pole, designed for clip-on mounting on 35 mm DIN rail in distribution panels. The D curve means magnetic tripping occurs at 12 x In (±20 %), so it handles inrush from motor or transformer loads without nuisance trips — the right choice for a 2 A branch feeding a small motor or solenoid bank. Breaking capacity is 10 kA Icu at 220–240 V AC (50/60 Hz) per IS/IEC 60947-2, with 15 kA at 12–48 V DC and 6 kA at 60 V DC — sufficient for most sub-distribution fault levels in industrial and commercial panels. It carries IS/IEC 60947-2 certification, pollution degree 3, overvoltage category IV, and suitability for isolation — approvals that cover most industrial and commercial installations across IEC-adopting markets. Width is 18 mm (2 x 9 mm pitches), so it occupies one standard DIN-rail module — important for panel fill-factor planning when packing multiple poles into a row. IP20 finger-safe front, tropicalisation class 2 per IEC 60068-1, and 95 % RH at 55 °C — suitable for enclosed distribution boards in humid or warm environments.","metaTitle":"Schneider Electric A9N1P02DIN Acti9 xC60 MCB, 2 A D Curve, 1","metaDescription":"Schneider Electric A9N1P02DIN Acti9 xC60 miniature circuit-breaker, 2 A rated, D curve, 1 pole, 10 kA breaking capacity at 240 V AC. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"77.5 mm","Range":"Acti9","Width":"18 mm","Colour":"White","Height":"85 mm","Standards":"IS/IEC 60947-2","Curve code":"D","9 Mm Pitches":"2","Control type":"Toggle","Network type":"AC DC","Product name":"XC60","Mounting mode":"Clip-on","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to IS/IEC 60947-2","Local signalling":"ON/OFF indication","Mounting support":"35 mm DIN rail","Pollution degree":"3","Range of product":"Acti9","Breaking capacity":"10 kA Icu at 220...240 V AC 50/60 Hz conforming to IS/IEC 60947-2 15 kA Icu at 12...48 V DC conforming to IS/IEC 60947-2 6 kA Icu at 60 V DC conforming to IS/IEC 60947-2","Device short name":"xC60","Network frequency":"50/60 Hz","Poles description":"1P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m","Device application":"Distribution","[In] rated current":"2 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to IS/IEC 60947-2","Electrical durability":"20000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"13 mm for top or bottom connection","Connections - terminals":"Tunnel type terminals (bottom) 16 mm² flexible Tunnel type terminals (bottom) 25 mm² rigid Biconnect (bottom)","IP degree of protection":"IP20","Magnetic tripping limit":"12 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"1","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to IS/IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IS/IEC 60947-2","[Ue] rated operational voltage":"220...240 V AC 50/60 Hz 12...48 V DC 60 V DC","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-30...70 °C","[Ics] rated service breaking capacity":"15 kA conforming to IS/IEC 60947-2 - 12...48 V DC 6 kA conforming to IS/IEC 60947-2 - 60 V DC 7.5 kA conforming to IS/IEC 60947-2 - 220...240 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"4 kV conforming to IS/IEC 60947-2","Comb busbar and distribution block compatibility":"Top: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9N1P02DIN/miniature-circuit-breaker-mcb-acti9-xc60-1p-2a-d-curve-10ka-is-iec609472/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N1P02DIN/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of A9N1P02DIN?","answer":"10 kA Icu at 220–240 V AC 50/60 Hz, 15 kA at 12–48 V DC, and 6 kA at 60 V DC, all per IS/IEC 60947-2."},{"question":"Where can I buy A9N1P02DIN and how is it quoted?","answer":"The A9N1P02DIN is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N1P02DIN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N1P02DIN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}