{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N1P04CGN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N1P04CGN","canonicalUrl":"https://aoctrl.com/schneider/A9N1P04CGN","factsUrl":"https://aoctrl.com/api/mcp/products/A9N1P04CGN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 xC60, miniature circuit breaker, A9N1P04CGN, 1P, 4 A, C curve, 10 kA Icn at 240 V AC, clip-on 35 mm DIN rail.","salesMarkdown":"The Schneider Electric A9N1P04CGN is a 1-pole miniature circuit breaker from the Acti9 xC60 range, rated at 4 A with a C-curve trip characteristic. It clips onto a standard 35 mm DIN rail and is built for distribution in residential and commercial AC networks at 220–240 V, 50/60 Hz. Rated breaking capacity is 10 kA Icn at 240 V AC, certified to IS/IEC 60898-1. The limitation class is 3 per the same standard, which means it lets through less energy during a short-circuit than a class 1 or 2 device, helping with downstream coordination. ## Integration and wiring Mounts via clip-on to 35 mm DIN rail.","metaTitle":"Schneider Electric A9N1P04CGN Acti9 xC60 MCB, 4 A, C Curve,","metaDescription":"Schneider Electric A9N1P04CGN Acti9 xC60 miniature circuit breaker, 4 A rated current, C curve, 1 pole, 10 kA breaking capacity at 240 V AC. Complies with IS/IEC 60898-1. Available","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"77.5 mm","Range":"Acti9","Width":"18 mm","Colour":"White","Height":"85 mm","Standards":"IS/IEC 60898-1","Curve code":"C","9 Mm Pitches":"2","Control type":"Toggle","Network type":"AC","Product name":"XC60","Mounting mode":"Clip-on","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to IS/IEC 60898-1","Local signalling":"ON/OFF indication","Mounting support":"35 mm DIN rail","Pollution degree":"3","Range of product":"Acti9","Breaking capacity":"10000 A Icn at 240 V AC 50/60 Hz conforming to IS/IEC 60898-1","Device short name":"xC60","Network frequency":"50/60 Hz","Poles description":"1P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m","Device application":"Distribution","[In] rated current":"4 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"13 mm for top or bottom connection","Connections - terminals":"Tunnel type terminals (bottom) 16 mm² flexible Tunnel type terminals (bottom) 25 mm² rigid Biconnect (bottom)","IP degree of protection":"IP20","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Separate block","Number of protected poles":"1","Product or component type":"Miniature circuit-breaker","Contact position indicator":"Yes","[Ue] rated operational voltage":"220...240 V AC 50/60 Hz","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-30...70 °C","Comb busbar and distribution block compatibility":"Top: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9N1P04CGN/miniature-circuit-breaker-mcb-acti9-xc60-1p-4a-c-curve-10000a-is-iec608981/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N1P04CGN/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of A9N1P04CGN?","answer":"10 kA Icn at 240 V AC, 50/60 Hz, certified to IS/IEC 60898-1. This is the maximum fault current the breaker can safely interrupt at that voltage."},{"question":"What does the C curve mean on this breaker?","answer":"The C curve means the magnetic trip is set to operate between 5 and 10 times the rated current (20–40 A for this 4 A unit). It's designed for circuits with moderate inrush, such as small motors, fluorescent lighting, or general-purpose socket outlets."},{"question":"What compliance documentation is available for A9N1P04CGN?","answer":"The breaker is certified to IS/IEC 60898-1 and carries tropicalisation treatment per IEC 60068-1. Standard compliance documentation (declaration of conformity, CE marking) is available from the manufacturer's support portal."},{"question":"Where can I buy A9N1P04CGN?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commitment."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N1P04CGN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N1P04CGN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}