{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9N1P04CIN","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9N1P04CIN","canonicalUrl":"https://aoctrl.com/schneider/A9N1P04CIN","factsUrl":"https://aoctrl.com/api/mcp/products/A9N1P04CIN","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 xC60, miniature circuit breaker, 1P, C-curve, 4 A, 10 kA Icu at 240 V AC, IS/IEC 60947-2, clip-on 35 mm DIN rail, white.","salesMarkdown":"The Schneider Electric A9N1P04CIN is a 1-pole miniature circuit breaker from the Acti9 xC60 family, rated 4 A with a C-curve trip characteristic. At 12–48 V DC the breaking capacity rises to 15 kA, and at 60 V DC it drops to 6 kA, which matters if you're using it in a DC control circuit. The toggle gives local ON/OFF indication. Thermal-magnetic trip technology covers both overload (thermal bimetal) and short-circuit (solenoid) protection in one unit. The part is certified to IS/IEC 60947-2, the standard for industrial circuit breakers — not the household IEC 60898. That means it's rated for isolation and carries a utilisation category A, so it's intended for distribution duty where selectivity with upstream breakers is designed in, not for direct motor starting. ## Integration into a panel Mounts via clip-on to 35 mm DIN rail. The white colour matches the rest of the Acti9 modular range for a clean panel layout.","metaTitle":"Schneider Electric A9N1P04CIN Acti9 xC60 MCB, 1P C-curve 4 A","metaDescription":"Schneider Electric A9N1P04CIN Acti9 xC60 miniature circuit breaker, 1-pole, C-curve, 4 A rated current, 10 kA breaking capacity per IS/IEC 60947-2. Active production, sourced to or","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"77.5 mm","Range":"Acti9","Width":"18 mm","Colour":"White","Height":"85 mm","Standards":"IS/IEC 60947-2","Curve code":"C","9 Mm Pitches":"2","Control type":"Toggle","Network type":"DC AC","Product name":"XC60","Mounting mode":"Clip-on","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to IS/IEC 60947-2","Local signalling":"ON/OFF indication","Mounting support":"35 mm DIN rail","Pollution degree":"3","Range of product":"Acti9","Breaking capacity":"10 kA Icu at 220...240 V AC 50/60 Hz conforming to IS/IEC 60947-2 15 kA Icu at 12...48 V DC conforming to IS/IEC 60947-2 6 kA Icu at 60 V DC conforming to IS/IEC 60947-2","Device short name":"xC60","Network frequency":"50/60 Hz","Poles description":"1P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m","Device application":"Distribution","[In] rated current":"4 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to IS/IEC 60947-2","Electrical durability":"20000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"13 mm for top or bottom connection","Connections - terminals":"Tunnel type terminals (bottom) 16 mm² flexible Tunnel type terminals (bottom) 25 mm² rigid Biconnect (bottom)","IP degree of protection":"IP20","Magnetic tripping limit":"8 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"1","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to IS/IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to IS/IEC 60947-2","[Ue] rated operational voltage":"220...240 V AC 50/60 Hz 12...48 V DC 60 V DC","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-30...70 °C","[Ics] rated service breaking capacity":"15 kA conforming to IS/IEC 60947-2 - 12...48 V DC 6 kA conforming to IS/IEC 60947-2 - 60 V DC 7.5 kA conforming to IS/IEC 60947-2 - 220...240 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"4 kV conforming to IS/IEC 60947-2","Comb busbar and distribution block compatibility":"Top: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9N1P04CIN/miniature-circuit-breaker-mcb-acti9-xc60-1p-4a-c-curve-10ka-is-iec609472/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9N1P04CIN/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy A9N1P04CIN and get current pricing?","answer":"This part is sourced to order through independent distribution. Submit an RFQ for current pricing and availability — confirmed at quote time, no stock or price figures published here."},{"question":"What is the breaking capacity of A9N1P04CIN at 240 V AC?","answer":"10 kA Icu at 220...240 V AC 50/60 Hz conforming to IS/IEC 60947-2. That's the maximum fault current it can safely interrupt at that voltage level."},{"question":"What compliance standards does A9N1P04CIN meet?","answer":"Certified to IS/IEC 60947-2, the industrial standard for circuit breakers. Tropicalisation class 2 per IEC 60068-1 and limitation class 3 per IS/IEC 60947-2 are also specified."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9N1P04CIN","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9N1P04CIN when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}